108
Options Guide
TX200
S6
Completion
Ê
Push system fan 1 (or 1&3) in the direction of the arrow until the lock
engages (2).
Ê
Connect the fan cable to the connector FAN1 (if there is a second fan cable,
connect this to connector FAN3) on the system board.
12.1.2 Installing system fan 2 (or 2&4)
The standard system fan 2 has just one fan cable; the redundant system fan
2&4 (dual fan, two fans are integrated internally) has two fan cables. The
procedure for installing both system fans is identical except for connecting the
fan cables.
Ê
Connect the fan cable to the connector FAN2 (if there is a second fan cable,
connect this to connector FAN4) on the system board.
Figure 92: Example: Installing system fan 2&4
Ê
Carefully insert (1) the air duct with the integrated system fan 2 (or 2&4).
Make sure that the locks of the air duct engage (2) in the housing bracket
and in the recess of the fixing plate (standard power supply) or the power
supply cage (redundant power supply).