352
Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
System board and components
14.2.3 Installing the CMOS battery
Figure 265: Installing the CMOS battery
Ê
At a slight angle, fit the new CMOS battery into its socket as shown (1).
V
CAUTION!
Ensure to insert the CMOS battery with the positive pole (label side)
facing up as shown (see close-up).
Ê
Fold down the CMOS battery (2) until it locks in place.
Ê
Ensure that the locking spring (3) is properly engaged.
14.2.4 Concluding steps
Ê
Dispose of the CMOS battery in accordance with local regulations
concerning special waste.
Ê
Ê