240
Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Expansion cards and backup units
9.5.6.2
Removing the defective BBU
Ê
Remove the BBU with the holder as described in section
BBU with the holder" on page 234
Ê
Remove the BBU from the holder as described in section
BBU from the holder" on page 235
.
Ê
Disconnect the BBU cable as described in section
cable from the BBU" on page 235
.
9.5.6.3
Installing the new BBU
Ê
Connect the BBU cable to the BBU as described in section
BBU cable to the BBU" on page 224
.
Ê
Install the new BBU in the BBU holder as described in section
BBU in the holder" on page 225
Ê
Install the BBU with the holder as described in section
9.5.6.4
Concluding steps
Ê
Ê
"Connecting the server to the mains" on page 74
Ê
"Switching on the server" on page 75
Ê
If applicable,
"Updating RAID controller firmware" on page 90
Ê
"Enabling SVOM boot watchdog functionality" on page 94
Note on BBU charging and calibration
The BBU may be deeply discharged due to extended storage time and wrongly
show as bad or defective in the ServerView RAID Manager.
In this case, the BBU will automatically enter a trickle charge cycle for recovery.
This initial charge may take up to 8 hours before the BBU will initiate a
recalibration cycle.
Ê
Enter the ServerView RAID Manager and check the current BBU status.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Summary of Contents for PRIMERGY TX150 S8
Page 22: ...Upgrade and Maintenance Manual TX150 S8 TX200 S7 Contents ...
Page 108: ...108 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Basic software procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Power supply units ...
Page 184: ...184 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Hard disk drives solid state drives ...
Page 196: ...196 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Fans ...
Page 274: ...274 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Processors ...
Page 348: ...348 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Front panel and external connectors ...
Page 388: ...388 Upgrade and Maintenance Manual TX150 S8 TX200 S7 System board and components ...