234
Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Expansion cards and backup units
9.5.4.1
Preliminary steps
Ê
"Disabling SVOM boot watchdog functionality" on page 80
Ê
"Shutting down the server" on page 50
Ê
"Disconnecting the server from the mains" on page 50
Ê
"Getting access to the component" on page 51
9.5.4.2
Removing the BBU with the holder
Figure 161: Removing the BBU holder from the chassis
Ê
Carefully disconnect the BBU cable from the RAID controller (1).
Ê
Lift up the green locking handle on the BBU holder (2, see close-up) while
sliding the BBU holder in the direction of the arrow as far as it will go (3).
I
After that, the hooks on the air duct will rest in the wide ends of the
keyhole slots on the holder.
Ê
Lift the BBU holder out of the chassis.
Summary of Contents for PRIMERGY TX150 S8
Page 22: ...Upgrade and Maintenance Manual TX150 S8 TX200 S7 Contents ...
Page 108: ...108 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Basic software procedures ...
Page 136: ...136 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Power supply units ...
Page 184: ...184 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Hard disk drives solid state drives ...
Page 196: ...196 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Fans ...
Page 274: ...274 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Processors ...
Page 348: ...348 Upgrade and Maintenance Manual TX150 S8 TX200 S7 Front panel and external connectors ...
Page 388: ...388 Upgrade and Maintenance Manual TX150 S8 TX200 S7 System board and components ...