112
Upgrade and Maintenance Manual
TX150 S8 / TX200 S7
Power supply units
6.2
Standard power supply
6.2.1
Basic information
There are two different power supply units:
Figure 37: Standard power supply unit 500 W and 800 W
6.2.2
Replacing the standard power supply unit
I
Replacing the standard power supply unit is illustrated by the example of
the power supply unit 500 W for the PRIMERGY TX150 S8.
6.2.2.1
Preliminary steps
Ê
"Disabling or suspending BitLocker functionality" on page 79
Ê
"Locating the defective server" on page 47
Ê
"Shutting down the server" on page 50
Ê
"Disconnecting the server from the mains" on page 50
1
Power supply unit 500 W for the PRIMERGY TX150 S8
2
Power supply unit 800 W for the PRIMERGY TX200 S7
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver