LSI 1078 controllers
Different configurations
V
ACHTUNG!
All unused cable ends have to be equipped with protective caps to avoid
short curcuits!
Ê
Lay the unused cable ends of the two SAS cables at suitable locations.
5.2.2
Configuration: Four HDDs using one LSI 1078
controller
Ê
Remove the storage blade as described in
section “Removing the storage
blade” on page 13
.
Ê
Open the storage blade as described in
section “Opening the storage blade”
on page 14
.
Prerequisites
No controller installed, HDDs not connected.
Figure 16: Configuration: Four HDDs using one LSI 1078 controller
Ê
Plug the controller into the contact strip (1) of the main boardrd #1 and fix it
with a screw C26192-Y10-C68 (blue circle).
Ê
Plug the connector HOST of the lower SAS cable into the SAS connector
MLC1 (2) on the controller.
Ê
Plug the connector P1 of the SAS cable into the connector on the HDD
diskbay 0/1 (3).
2
1
3
4