213
PRIMERGY RX200 S4 User's Guide
Server Management Tools error messages
The following error messages may appear while executing Server Management Tools. Perform the
corresponding resolution listed in the table. If messages other than the following are displayed, contact
an office listed in the "Contact Information" of the "Start Guide".
iRMC reports sensor status: CRITICAL
DIMM-*D (*: 1 to 3)
Memory *D error. Replace the displayed memory pair. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
DIMM-*D (*: 1 to 3)
iRMC reports sensor status: CRITICAL PCI
Slot* (*: 1 to 3)
The PCI slot is abnormal. Check the error log and replace the
PCI card. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
iRMC reports sensor status: WARNING PCI
Slot* (*: 1 to 3)
iRMC reports sensor status: CRITICAL CPU*
(*: 1 or 2)
The CPU is abnormal. Check the error log and replace the faulty
CPU. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
iRMC reports sensor status: WARNING
CPU* (*: 1 or 2))
table: List of Server Management Tools error messages
Message
Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted. Insert the proper floppy
disk ("Server Management Tools" floppy disk), and
then press the [R] key.
ERROR:Fail to create data file.
The following are possible causes. Check the floppy
disk status again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted. Insert the proper
floppy disk, and then retry.
• The floppy disk contains abnormal contents. Create
the "Server Management Tools" floppy disk again. If
this occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.
ERROR:Fail to write 1st CMOS data into data file. nn
ERROR:Fail to write 2nd CMOS data into data file. nn
ERROR:Fail to write ESCD data into the data file. nn
ERROR:Fail to write SEEPROM data into the data file.
nn
ERROR:Fail to open data file.
The file for recovering the BIOS information does not
exist on this floppy disk. Insert the floppy disk on
which the BIOS information was stored, and then retry.
ERROR:Fail to write 1st CMOS data into system. nn
The following are possible causes. Check the floppy
disk status again.
• The floppy disk is not inserted. Insert the proper
floppy disk, and then retry.
• A different model or an unsupported version of
BIOS information. Insert the proper floppy disk, and
then retry.
• The floppy disk contains abnormal contents. Create
the "Server Management Tools" floppy disk again. If
this occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.
ERROR:Fail to write 2nd CMOS data into system file.
nn
ERROR:Fail to write ESCD data into system file. nn
ERROR:Fail to write SEEPROM data into system. nn
table: List of POST error messages
Message
Description
Summary of Contents for Primergy RX200 S4
Page 12: ...12 ...
Page 70: ...70 Chapter 3 OS Installation ...
Page 128: ...128 Chapter 5 High Reliability Tools ...
Page 200: ...200 Chapter 7 Configuring Hardware and Utilities ...
Page 238: ...238 Chapter 8 Operation and Maintenance ...
Page 264: ...264 Appendix ...