145
PRIMERGY RX200 S4 User's Guide
6
Select [Save Changes & Exit] in the [Exit] menu and press the [Enter] key.
A message confirming whether to save the BIOS setting change is displayed.
7
Select [Yes] and press the [Enter] key.
After the system restarts, the memory sparing configuration becomes effective.
6.4.4 How to Install or Remove Memory Modules
This section explains how to install/remove memory modules.
1
Turn off the power and all peripheral devices, and pull the server out from the
rack to remove the top cover.
"6.2 Attaching/Removing the Top Cover" (p.132)
2
Touch a metal part of the server to discharge static electricity.
3
Remove the fan duct.
Lift and remove the fan duct.
• After the server shutdown, memory modules remain very hot. Wait for a
sufficient period of time after the server shutdown before removing memory
modules. Failure to do so may cause burns.
[Front]
Fan duct