60
Operating Manual
CX400
S2
Troubleshooting and tips
8.2
Drives reported as “dead” when starting
system
This error message can occur when the onboard SAS controller has RAID
functionality or the server enclosure is equipped with a PCI RAID controller.
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller utility.
8.3
Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê
Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê
Remove and reinstall the drive while the system is switched ON.
If the drive continues to be shown as defective, then replace it.