Important information
V
CAUTION!
●
Ensure that the power sockets on the device and the properly
grounded power outlets are freely accessible.
●
The On/Off button or the main power switch (if present) does not
isolate the device from the mains power supply. To disconnect it
completely from the mains power supply, unplug all network power
plugs from the properly grounded power outlets.
●
Always connect the server enclosure and the attached peripherals to
the same power circuit. Otherwise you run the risk of losing data if,
for example, the server enclosure is still running but a peripheral
device (e.g. memory subsystem) fails during a power outage.
●
Data cables must be adequately shielded.
●
Ethernet cabling has to comply with EN 50173 and EN 50174-1/2
standards or ISO/IEC 11801 standard respectively. The minimum
requirement is a Category 5 shielded cable for 10/100 Ethernet, or a
Category 5e cable for Gigabit Ethernet.
●
Route the cables in such a way that they do not create a potential
hazard (make sure no-one can trip over them) and that they cannot
be damaged. When connecting the server enclosure, refer to the
relevant instructions in this manual.
●
Never connect or disconnect data transmission lines during a storm
(risk of lightning hazard).
●
Make sure that no objects (e.g. jewelry, paperclips etc.) or liquids can
get inside the server enclosure (risk of electric shock, short circuit).
●
In emergencies (e.g. damaged casing, controls or cables, penetration
of liquids or foreign bodies), switch off the server enclosure
immediately, remove all power plugs and contact your sales outlet or
customer service team.