11.3
Minimum startup configuration
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Ê
Shut down the server as described in section
"Shutting down the server
node" on page 43
.
Ê
Take the system down to its minimum startup configuration.
Ê
Connect a keyboard, mouse and display to the server.
Ê
Switch on the server as described in section
"Switching on the server node"
on page 63
.
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
Field Replaceable Units (FRU)
Component
Notes and reference
System board
no UFM or expansion cards installed
CPU with CPU heat sink
installed in socket CPU0
1 memory module
installed in slot A1 or C1, see section
"Memory
sequence" on page 224
1 Power supply unit
Table 13: Minimum startup configuration - components
Cable
Notes and reference
2 SATA cables
Table 14: Minimum startup configuration - cables