BX924 S4
Upgrade and Maintenance Manual
77
Basic software procedures
iRMC recovery procedure
The iRMC recovery is performed via the
FlashDisk
menu executed from a
bootable USB memory stick. For detailed information refer to the "Integrated
Remote Management Controller" user guides available online.
I
For the Japanese market, follow the instructions provided separately.
Ê
Shut down the server blade as described in section
"Shutting down the
server blade" on page 52
.
Ê
Connect the monitor, keyboard, mouse and the bootable USB memory stick
to the port on the front of the server blade using the Y cable, see the
Operating Manual.
Ê
Switch on the server blade while as described in section
"Switching on the
server blade" on page 60
to boot from the USB memory stick.
After completion of the boot operation, the
FlashDisk
menu opens.
Ê
Select
Recovery _L
to carry out the recovery flash for firmware image 1 (low
firmware image).
Ê
Select
Recovery _U
to carry out the recovery flash for firmware image 2 (high
firmware image).
Ê
Once the update operation has been completed, click on
Exit
, to close the
FlashDisk
menu.
Ê
Shut down the server blade as described in section
"Shutting down the
server blade" on page 52
.
Ê
Remove the Y-cable.
Ê
Switch on the server blade as described in section
"Switching on the server
blade" on page 60
.
Ê
You can now put the server blade back into operation.