BX924 S4
Upgrade and Maintenance Manual
133
Mezzanine cards
●
If an FC mezzanine card is installed in slot 1, at least one FC connection
blade must be installed in CB slot 2 of the system unit.
●
If a 1 Gb Ethernet mezzanine card is installed in slot 2 of a server blade, at
least one 1 Gb Ethernet connection blade must be installed in CB slot 3 or
in CB slot 4 of the system unit.
●
If a 10 Gb Ethernet mezzanine card is installed in slot 2 of a server blade, at
least one 10 Gb Ethernet connection blade must be installed in CB slot 3 or
in CB slot 4 of the system unit.
●
If an FC mezzanine card is installed in slot 2, at least one FC connection
blade must be installed in CB slot 3 or in CB slot 4 of the system unit.
●
If an Infiniband mezzanine card is installed in slot 2, an Infiniband connection
blade must be installed in CB slots 3 and 4 of the system unit.
●
If a SAS/SAS RAID mezzanine card is installed in slot 2, at least one SAS
connection blade must be installed in fabric 3.
●
You can install a combination of FC, Ethernet and Infiniband mezzanine
cards in a server blade. In this case, the Ethernet mezzanine card should be
installed in slot 1 and the FC or Infiniband mezzanine card in slot 2 of the
server blade.