
108
Upgrade and Maintenance Manual
BX924
S4
Hard disk drives / Solid state drives
©
c
o
gn
ita
s.
G
e
se
lls
ch
ft fü
r T
ech
n
ik
-D
o
ku
m
en
ta
tio
n
m
b
H
2
0
13
Pf
a
d:
C
:\P
ro
g
ra
m
m
e
\F
C
T
\ti
m
_a
pp
\ti
m
_l
oca
l\w
or
k\PI
C
H
O
L\
O
B
J_
D
O
KU
-2
0
56
5-
00
1.
fm
6.4
Removing HDD/SSD
6.4.1
Required tools
●
Preliminary and concluding steps: tool-less
●
Removing a HDD/SSD module:
– Phillips PH2 / (+) No. 2 screw driver
6.4.2
Preliminary steps
Before removing a HDD/SSD module, perform the following steps:
Only applicable for removing intact HDD/SSD modules:
Ê
Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online.
Ê
If applicable, open the rack door as described in section
"Opening the rack
door" on page 51
.
Ê
Locate the desired server blade as described in section
"Locating the
defective server blade" on page 43
.
Ê
Shut down the server blade as described in section
"Shutting down the
server blade" on page 52
.
Upgrade and Repair Units (URU)
Average task duration: 15 minutes