Concluding steps
Perform the following procedures to complete the task:
Ê
Shift the drive into the connector on the mounting frame as described in
section
"Installing SSD 0" on page 101
or
"Installing HDD/SSD 1" on
page 103
.
Ê
Tighten the 4 screws to the mounting frame as described in
"Installing
SSD 0" on page 101
or
"Installing HDD/SSD 1" on page 103
.
Ê
Reinstall the HDD/SSD to their original mounting platforms as described in
section
"Installing HDD/SSD" on page 99
.
Ê
If applicable, install the mezzanine carrier as described in chapter
"Installing
mezzanine cards" on page 134
.
Ê
Close the server blade as described in section
"Closing the server blade" on
page 56
.
Ê
Reinstall and secure the server blade in the system unit as described in
section
"Installing the server blade in the system unit" on page 57
.
Ê
If applicable, close the rack door as described in section
"Closing the rack
door" on page 62
.
Ê
If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section
"Enabling