C141-E110-02EN
5 - 52
Table 5.8 Features Register values (subcommands) and functions (2/2)
X’D5’
SMART Read Logging Data:
This subcommand is used to transfer 512-byte logging data to the host.
The setting of SN register is described as following.
Log Sector Address
01h (SC register 01h):
SMART Error Log
(See Table 5.11)
06h (SC register 01h):
SMART Self Test Log
(See Table 5.12)
80-9Fh:
Host vendor specific
When the device receives these subcommands, it asserts the BSY bit and transfers
512-byte logging data to the host, then clears the BSY bit.
X’D6’
SMART Write Logging Data:
This subcommand is used to transfer 512-byte logging data from the host, and saves
these data on the media.
Log Sector Address
80-9Fh:
Host vendor specific
When the device receives this subcommand, it receives 512-byte logging data from
the host, and asserts the BSY bit and saves 512-byte data on the media, then clears
the BSY bit.
X’D8’
SMART Enable Operations:
This subcommand enables the failure prediction feature. The setting is maintained
even when the device is turned off and then on.
When the device receives this subcommand, it asserts the BSY bit, enables the
failure prediction feature, then clears the BSY bit.
X’D9’
SMART Disable Operations:
This subcommand disables the failure prediction feature. The setting is maintained
even when the device is turned off and then on.
When the device receives this subcommand, it asserts the BSY bit, disables the
failure prediction feature, then clears the BSY bit.
X’DA’
SMART Return Status:
When the device receives this subcommand, it asserts the BSY bit and saves the
current device attribute values. Then the device compares the device attribute values
with insurance failure threshold values. If there is an attribute value exceeding the
threshold, F4h and 2Ch are loaded into the CL and CH registers. If there are no
attribute values exceeding the thresholds, 4Fh and C2h are loaded into the CL and
CH registers. After the settings for the CL and CH registers have been determined,
the device clears the BSY bit.
X’DB’
SMART Enable/Disable Automatic Off-line:
The device that receives this subcommand enables (SC register
≠
00h) or disables
(SC register = 00h) automatic off-line data collection. The condition is maintained
even when the device is turned off and turned on.
When the failure prediction feature and automatic off-line data collection are
enabled, an off-line data collection shall be performed regardless of host issued
command after more than 4 hours passed since power-on or the previous off-line
data collection.
When the device receives this subcommand, it asserts the BSY bit, enables or
disables automatic off-line data collection, then clears the BSY bit.
Summary of Contents for MPG3xxxAT
Page 1: ...C141 E110 02EN MPG3xxxAT DISK DRIVES PRODUCT MANUAL ...
Page 3: ...This page is intentionally left blank ...
Page 15: ...This page is intentionally left blank ...
Page 31: ...C141 E110 02EN 3 2 Figure 3 1 Dimensions ...
Page 47: ...This page is intentionally left blank ...
Page 67: ...This page is intentionally left blank ...
Page 177: ...This page is intentionally left blank ...
Page 201: ......