C141-E110-02EN
4 - 7
4.5
Self-calibration
The disk drive occasionally performs self-calibration in order to sense and calibrate mechanical
external forces on the actuator, and VCM torque. This enables precise seek and read/write
operations.
4.5.1
Self-calibration contents
(1)
Sensing and compensating for external forces
The actuator suffers from torque due to the FPC forces and winds accompanying disk revolution.
The torque vary with the disk drive and the cylinder where the head is positioned. To execute
stable fast seek operations, external forces are occasionally sensed.
The firmware of the drive measures and stores the force (value of the actuator motor drive
current) that balances the torque for stopping head stably. This includes the current offset in the
power amplifier circuit and DAC system.
The forces are compensated by adding the measured value to the specified current value to the
power amplifier. This makes the stable servo control.
To compensate torque varying by the cylinder, the disk is divided into 28 areas from the
innermost to the outermost circumference and the compensating value is measured at the
measuring cylinder on each area at factory calibration. The measured values are stored in the SA
cylinder. In the self-calibration, the compensating value is updated using the value in the SA
cylinder.
(2)
Compensating open loop gain
Torque constant value of the VCM has a dispersion for each drive, and varies depending on the
cylinder that the head is positioned. To realize the high speed seek operation, the value that
compensates torque constant value change and loop gain change of the whole servo system due to
temperature change is measured and stored.
For sensing, the firmware mixes the disturbance signal to the position signal at the state that the
head is positioned to any cylinder. The firmware calculates the loop gain from the position signal
and stores the compensation value against to the target gain as ratio.
For compensating, the direction current value to the power amplifier is multiplied by the
compensation value. By this compensation, loop gain becomes constant value and the stable
servo control is realized.
To compensate torque constant value change depending on cylinder, whole cylinders from most
inner to most outer cylinder are divided into 15 partitions at calibration in the factory, and the
compensation data is measured for representative cylinder of each partition. This measured value
is stored in the SA area. The compensation value at self-calibration is calculated using the value
in the SA area.
Summary of Contents for MPG3xxxAT
Page 1: ...C141 E110 02EN MPG3xxxAT DISK DRIVES PRODUCT MANUAL ...
Page 3: ...This page is intentionally left blank ...
Page 15: ...This page is intentionally left blank ...
Page 31: ...C141 E110 02EN 3 2 Figure 3 1 Dimensions ...
Page 47: ...This page is intentionally left blank ...
Page 67: ...This page is intentionally left blank ...
Page 177: ...This page is intentionally left blank ...
Page 201: ......