Servo frame format
As the servo information, the drive uses the two-phase servo generated from the gray code and
Pos A to D. This servo information is used for positioning operation of radius direction and
position detection of circumstance direction.
The servo frame consists of 6 blocks; write/read recovery, servo mark, preamble, gray code, Pos
A to D and PAD. Figure 4.6 shows the servo frame format.
Figure 4.6
126 Servo frames in each track
0.72
µ
s
1.81
µ
s
ASM
SSM
SCD
PosA
PosB
PosC
PosD
PAD
R/W Recovery Field
6.63
µ
s
DATA
DATA
DATA
88.18
µ
s
Servo
Frame
Servo
Frame
0.16
µ
s
0.17
µ
s
0.53
µ
s
0.74
µ
s
0.56
µ
s
0.56
µ
s
0.56
µ
s
0.80
µ
s
PA