7.2 Sense Data Analysis
C141-E198
7-3
7.2
Sense Data Analysis
7.2.1
Error information indicated with sense data
Subsection 7.2.2 onwards explain troubleshooting using sense data.
Table 7.1 lists the definition of sense data. For details of sense data, refer to the Fibre Channel
Interface Specifications.
Table 7.1
Definition of sense data
Sense data
Sense
key
Sense
Code
Sub
Sense
Code
00 00 00
Operation
was
normal.
3
0C
03
A write to a disk terminated abnormally.
4 32
40
44
C4
01
xx
xx
xx
Failed to update the defect list due to a disk medium write error, etc.
An error occurred in power-on self-diagnosis.
A hardware error occurred inside IDD.
A drive error occurred.
1
3
1x
1x
xx
xx
A disk read error occurred.
A disk read error occurred.
E
1D
00
Data discrepancy found by VERIFY command byte check.
5
2x
xx
A SCSI error, such as an invalid operation code, occurred.
3D
00
The Reserve bit of the IDENTIFY message was set to 1.
B
47
00
A CRC error occurred in the fibre channel loop.
B
49
00
An unmounted or inappropriate message was received.
B
4D
xx
Before completion of a command, a command with the same tag
number was issued.
B
4E
00
An overlap command was issued.
Definition
Summary of Contents for MAS3367FC
Page 1: ...C141 E198 02EN MAS3735FC MAS3367FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 20: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 62: ...Installation Requirements 4 10 C141 E198 Figure 4 10 SCA2 type connector ...
Page 108: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 113: ......
Page 114: ......