2.1 Hardware Specifications
C141-E198
2-5
(*1)
For detail condition, see Section 4.1.
(*2)
Vibration applied to the drive is measured at near the mounting screw hole on the frame as much as
possible.
(*3)
At random seek write/read and default on retry setting with log sweep vibration.
(*4)
At power-off state after installation
Vibration displacement should be less than 2.5 mm.
(*5)
Input voltages are specified at the drive connector side, during drive ready state.
(*6)
High frequency noise (over 20MHz) is less than 100 mVp-p.
2.1.4 Error
rate
Errors detected during initialization and replaced by alternate block assignments are not included in
the error rate. Data blocks to be accessed should be distributed over the disk medium equally.
(1)
Unrecoverable error rate
Errors which cannot be recovered within 63 retries and ECC correction should not exceed 1 per 10
15
bits.
Data loss
For MAS series, Reed Solomon codes are applied for their ECC. The
sector-data is divided into 4 interleaving sectors, and ECC is
performed in each sector where the maximum number of errors (up to
5 byte) can be corrected. [Total maximum byte: 5 byte
×
4 ( interleave)
= 20 byte]
If the error of read sector keeps allowable error byte number,
correction is performed. However, if error byte exceeds its allowable
number, correction may not be performed properly.
(2)
Positioning error rate
Positioning errors which can be recovered by one retry should be 10 or less per 10
8
seeks.
2.1.5 Reliability
(1)
Mean Time Between Failures (MTBF)
MTBF of the IDD during its life time is 1,2000,000 hours (operating: 24 hours/day, 7 days/week
average DE surface temperature: 50°C or less).
Summary of Contents for MAS3367FC
Page 1: ...C141 E198 02EN MAS3735FC MAS3367FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 20: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 62: ...Installation Requirements 4 10 C141 E198 Figure 4 10 SCA2 type connector ...
Page 108: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 113: ......
Page 114: ......