4.1 Mounting Requirements
C141-E198
4-5
(3)
Limitation of bottom-mounting
Use all 4 mounting holes on the bottom face.
(4) Environmental
temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured 3 cm
from the disk drive. At designing the system cabinet, consider following points.
•
Make a suitable air flow so that the DE surface temperature does not exceed 60°C.
•
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring temperature of specific ICs and the DE. These measurement results should be
within a criteria listed in Table 4.1.
•
Keeping the DE surface temperature at 50
°
C or below at ambient temperature 25
°
C, which is a
condition for assuring an MTBF of 1,200,000 hours, requires an air flow of 0.7 m/s.
Table 4.1
Surface temperature check point
No. Measurement
point Criteria
1
Center of DE cover
60°C
2
Read channel LSI
88°C
3 VCM/SPM
Driver
92°C
4 HDC
90°C
5 MPU
91°C
1
2
4
5
3
Figure 4.5 Surface temperature measurement points
Summary of Contents for MAS3367FC
Page 1: ...C141 E198 02EN MAS3735FC MAS3367FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 20: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 62: ...Installation Requirements 4 10 C141 E198 Figure 4 10 SCA2 type connector ...
Page 108: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 113: ......
Page 114: ......