3.2 Logical Data Block Addressing
C141-E198
3-9
3.1.5 Format
capacity
The size of the usable area for storing user data on the IDD (format capacity) varies according to the
logical data block or the size of the spare sector area. Table 3.2 lists examples of the format capacity
when the typical logical data block length and the default spare area are used. The following is the
general formula to calculate the format capacity.
[Number of sectors of each zone] = [number of sectors per track
×
number of tracks per cell –
number of alternate spare sectors per cell]
×
[number of cells in the zone]
[Formatted capacity] = [total of sectors of all zones]
÷
[number of physical sectors in logical block]
×
[logical data block length]
The following formula must be used when the number of logical data blocks are specified with the
parameter in the MODE SELECT or MODE SELECT EXTENDED command.
[Format capacity] = [logical data block length]
×
[number of logical data blocks]
The logical data block length, the maximum logical block address, and the number of the logical data
blocks can be read out by a READ CAPACITY, MODE SENSE, or MODE SENSE EXTENDED
command after initializing the disk medium.
Table 3.2
Format capacity
Model
Data heads
Data block length
User blocks Format capacity (GB)
MAS3735FC 8
143,552,136
73.49
(*)
MAS3367FC 4
512
71,819,496 36.77
(*)
(*) 1GB = 1,000,000,000 bytes
Note:
Total number of spare sectors is calculated by adding the number of spare sectors in each primary
cylinder and the number of sectors in the alternate cylinders.
3.2
Logical Data Block Addressing
Independently of the physical structure of the disk drive, the IDD adopts the logical data block
addressing as a data access method on the disk medium. The IDD relates a logical data block address
to each physical sector at formatting. Data on the disk medium is accessed in logical data block
units. The INIT specifies the data to be accessed using the logical data block address of that data.
The logical data block addressing is a function whereby individual data blocks are given addresses of
serial binaries in each drive.
Summary of Contents for MAS3367FC
Page 1: ...C141 E198 02EN MAS3735FC MAS3367FC DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 4: ...This page is intentionally left blank ...
Page 8: ...This page is intentionally left blank ...
Page 12: ...This page is intentionally left blank ...
Page 20: ...This page is intentionally left blank ...
Page 36: ...This page is intentionally left blank ...
Page 52: ...This page is intentionally left blank ...
Page 62: ...Installation Requirements 4 10 C141 E198 Figure 4 10 SCA2 type connector ...
Page 108: ...This page is intentionally left blank ...
Page 110: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 113: ......
Page 114: ......