6-14
C141-E185
Table 6.2
System-level field troubleshooting
Item
Recommended work
DC power cable
Check that the power cable is correctly connected to the disk drive and
power supply unit.
Check that the DC voltage is within the specified range (±5%).
Check that the +5 VDC value (pins 3 and 4 of the power connector) is
4.75 to 5.25 VDC.
DC power level
Check that the +12 VDC supply (pins 1 and 2 of the power connector of
disk drive) is 11.4 to 12.6 VDC.
Make sure the maximum ripple peak-to-peak value of +5 VDC is within
250 mV and +12 VDC is within 250 mV.
Electrical noise
Make sure the high frequency noise (over 20 MHz) is less than 100 mVp-p.
Interface cable connection
Check that the SCSI interface cable is correctly connected between the disk
drive and controller.
Terminating resistors
For a daisy chain connection, check the terminating resistor on the last disk
drive only. For a star-burst connection, check that the terminating resistor
is correctly mounted on all disk drives.
Drive selection address
Check that the disk SCSI ID is set correctly.
Plug setup
Check that the jumpers on the PCA are set so that the disk drive and host
computer operate normally. See Section 5.3.
System cables
Check that all system cables are connected correctly.
System diagnostic test
When possible, execute the system level diagnostic routine as explained in
the host computer manual. This gives a detailed report of a possible fault.
Check the AC voltage from the power supply. Check the DC voltage level
at the power connector for the disk drive.
If the AC voltage level is abnormal or there is a lot of electrical noise,
notify the user of the error.
If the DC voltage level is unstable, replace the power supply unit.
Intermittent or nonfatal errors
If possible, replace the disk drive. If replacing the disk drive does not
eliminate the error, the removed disk drive is probably not faulty. To
continue error analysis, refer to the hardware and software manuals
supplied with the system.
Summary of Contents for MAS3184NC - Enterprise 18.4 GB Hard Drive
Page 1: ...C141 E185 01EN MAS3735NC NP MAS3367NC NP MAS3184NC NP DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Page 10: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 122: ...This page is intentionally left blank ...
Page 126: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blankw ...
Page 129: ......
Page 130: ......