3-4. Details of control input function
¢
Operation/Stop mode 1
•
In the case of "Edge" input
Function
setting
External input and
output PCB
External input
Input signal
Command
Rotary
switch
SW2
46-00
—
Input of indoor unit
Terminal
Off → On
Operation
On → Off
Stop
1
Edge
External input and
output PCB
Ex IN 1
Off → On
Operation
On → Off
Stop
Remote controller
On
Off
Indoor unit operation
On
Ex IN 1
On
Off
•
In the case of "Pulse" input
Function
setting
External input and
output PCB
External input
Input signal
Command
Rotary
switch
SW2
46-00
1
Pulse
External input and
output PCB
Ex IN 1
Pulse
Operation
Ex IN 2
Stop
On
Remote controller
On
Off
Indoor unit operation
Ex IN 1
On
Off
On
Off
Ex IN 2
NOTES:
• The last command has priority.
• The indoor units within the same remote controller group operates in the same mode.
3-4. Details of control input function
- (05-16) -
3. External input and output (For indoor unit)
FIELD
WORKING
FIELD
WORKING
Summary of Contents for General AOHG45KRTA
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2022 01 24 SR_CH01_AR040EG_01 ...
Page 12: ...2 2 Outdoor unit 01 6 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 04 07 SR_CH02_AR040EG_02 ...
Page 33: ...3 TROUBLESHOOTING 2022 04 07 SR_CH03_AR040EG_02 ...
Page 36: ......
Page 93: ...4 CONTROL AND FUNCTIONS 2022 02 04 SR_CH04_AR040EG_01 ...
Page 127: ...5 FILED WORKING 2022 04 07 SR_CH05_AR040EG_02 ...