Commissioning Test
Fujitsu and Fujitsu Customer Use Only
3-12
BroadOne GX4000 Manual (R3.0) issue 1.03
Table 3.7 Alarm and Severity of Alarm Summary
1
EQPT
Processor Failure
E
2
EQPT
Start-up Failure
E
3
EQPT
Internal Heath Check Failure
E
4
EQPT
Internal Clock Failure
E
5
EQPT
PLL Failure
E
6
EQPT
TX Block Failure
E
7
EQPT
XFP Optical Module Absence
E
8
EQPT
XFP Optical TX Block Failure
E
9
EQPT
SFP Optical TX Block Failure
E
10
EQPT
10G PHY Failure
E
11
EQPT
1G PHY Failure
E
12
EQPT
Internal Data Failure
E
13
EQPT
IO Failure
E
14
EQPT
FPGA Upload NG
E
15
EQPT
Software Upload NG
E
16
EQPT
FPGA Image Select NG
E
17
EQPT
FPGA Config Invalid (nStatus/CONF_DONE Invalid)
E
18
EQPT
Internal Power Source Failure
E/W/I
19
EQPT/ENVR
High Temperature
E/I
20
ENVR/ENVR
Laser Temperature High
E/I
21
ENVR
Low Temperature
W/I
22
ENVR
Laser Temperature Low
W/I
23
(MON INFO)
L2SW Failure
W
24
(MON INFO)
FPGA Config RAM CRC Failure
I
25
EXT
Sync-E PLL DPLL0 UNLOCK
W
26
EXT
Sync-E PLL DPLL1 UNLOCK
W
27
EXT
Sync-E PLL DPLL0 HOLDOVER
W
28
EXT
Sync-E PLL DPLL1 HOLDOVER
W
29
EQPT
Optical Power Transmitted Out of Range
E
30
EXT
External Clock Degrade on Sync Ethernet Line
W
31
EXT
External Clock Degrade on Sync Ethernet CRPI
W
32
EXT
External Clock Degrade on Sync Ethernet L2SW
W
33
EXT
XFP RX_NR (Any condition leading to invalid data on the RX path)
W
34
EXT
XFP RX_LOSS (mirroring hardware output pin)
I
35
EXT
XFP RX_CDR Unlocked (Unlocked: Loss of Lock of RX side CDR)
W
36
EXT
XFP MOD_NR (Module Not Ready (mirroring hardware output pin)
W
37
EXT
10G PHY SIDE-MAC Transmit FIFO Underrun
W
38
EXT
10G PHY SIDE-Transmit Frame Abort
W
39
EXT
10G PHY SIDE-RX Symbol Error Count
W
40
EXT
10G PHY SIDE-RX Unsupported Opcode Count
W
41
EXT
10G PHY SIDE-RX CRC Error Count
W
42
EXT
10G PHY SIDE-RX Undersize Count
W
43
EXT
10G PHY SIDE-RX Undersize with CRC Error Count
W
44
EXT
10G PHY SIDE-RX MAC Client Data Length Mismatch Regal Length Field
W
45
EXT
10G PHY SIDE-RX Oversize Count
W
46
EXT
10G PHY SIDE-RX Oversize with CRC Error Count
W
47
EXT
Optical Power Received Degrade
W/I
48
EXT
Optical Power Received Out of Range
W/I
49
EXT
SFP RX_LOSS (RX Loss of Signal, mirroring hardware output pin)
I
50
MON INFO
LINE XAUI Packet Discard
W
51
MON INFO
LINE XAUI Packet Overflow
W
52
MON INFO
Optical Power Transmitted Degrade
W
53
MON INFO
Line Loopback Test
I
LINE
Clock
No
Category
Cause Factor
Status Description
Level
Hardware
Summary of Contents for BroadOne GX4000 R3.0 Series
Page 7: ... ...