Installation
Fujitsu and Fujitsu Customer Use Only
2-4
BroadOne GX4000 Manual (R3.0) issue 1.03
Power Supply Feed through Circuit Breaker in case of AC Power Feed
2.3
Unpacking
Verify that the item received are compliant with the packing list.
If any part of the equipment is damaged, contact Fujitsu Limited
representative for repair or replacement instruction.
The ODU is packaged in two (2) separate boxes. In addition, the optional
items such as cables are packaged in a separate container.
2.4
Antenna Pole Mounting
Two types of parabolic antenna with 1-feet (30 cm) or 2-feet (60 cm)
diameters with antenna adapter are available.
Integrated antenna with ODU interface (1-feet or 2-feet diameter).
With these antennas, ODU is directly attached on the antenna.
2.4.1 Antenna Pole Mounting Overview
ODU and parabolic antenna is mounted on tubular self-supported pole
having diameter of 60.5 mm x 1,750 mm height.
If ODU with antenna is installed on tower using another type of structure
(e.g., square-section tower), special installation kits must be used for this
support.
CAUTION
: For ODU with antenna mounting, following precautions must
always be taken:
Allow enough clearance (± 10°) about the alignment axis. Leave also
adequate space around the ODU with antenna to allow easy mounting;
Make sure that nothing may obstruct the radio path, even partially or
especially in the line of sight;
Keep enough room for access to the ODU with antenna for
commissioning test and maintenance test;
Install proper lightning rod and ground earthling;
Station Power Supply
System (AC)
CB
Circuit Breaker (CB)
provided by Customer
Approved component
according to IEC60934
Rating: 253V/0.25A min.
SPD
Surge Protective Device
(SPD)Provided by Customer
Rating: Up <= 2.5 kV
Summary of Contents for BroadOne GX4000 R3.0 Series