Fujitsu and Fujitsu Customer Use Only
Installation
BroadOne GX4000 Manual (R3.0) issue 1.03
2-23
Table 2.8.4e Pin Assignment of Connector (AC Power Supply)
Item
GX4000 Side
Ext Equipment Side
Signal
Direction
Connector
Pin No.
Label
Connector
1
L
-
Water-
Proof,
Round 4P
1
TM1
M4 crimp
2
N
-
2
TM2
M4 crimp
3
G (*1)
-
3
TM3
M4 crimp
4
G (*1)
-
5
G (*2)
-
shield
TM4
M4 crimp
Note-*1: Pin-3 of GX4000 side and TM3 is connected by two cables.
Note-*2: Shield of cable and TM4 is connected.
Table 2.8.4f Pin Assignment of Connector (Ether Electrical Cable)
Item
GX4000 Side
Ext Equipment Side
Signal
Direction
Connector
Pin No.
Label
Connector
1
TD(+)
-
Water-
Proof,
RJ-45
1
1
RJ-45
2
TD(-)
-
2
2
3
RD(+)
-
3
3
4
-
-
4
4
5
-
-
5
5
6
RD(-)
-
6
6
7
-
-
7
7
8
-
-
8
8
Table 2.8.4g Pin Assignment of Connector (I/O Cable)
Item
GX4000 Side
Ext Equipment Side
Signal
Direction
Connector
Pin No.
Label
Connector
1
CLOSE ALM
-
Water-
Proof,
Round 8P
1
TM1
M4 crimp
2
OPEN ALM
-
2
TM2
M4 crimp
3
COMMON
-
3
TM3
M4 crimp
4
NC
-
4
-
5
NC
-
5
-
6
NC
-
6
-
7
EXT XRST
INPUT
7
TM4
M4 crimp
8
SG
-
8
TM5
M4 crimp
9
FG (*1)
-
External
-
10
FG (*2)
-
-
-
TM5
M4 crimp
Note-*1: Cable shield and connector out of GX4000 is connected.
Note-*2: Cable shield and TM5 is connected.
Summary of Contents for BroadOne GX4000 R3.0 Series