![Fujitsu BroadOne GX4000 R3.0 Series User Manual Download Page 62](http://html.mh-extra.com/html/fujitsu/broadone-gx4000-r3-0-series/broadone-gx4000-r3-0-series_user-manual_120465062.webp)
Fujitsu and Fujitsu Customer Use Only
Installation
BroadOne GX4000 Manual (R3.0) issue 1.03
2-19
2.8
Cable & Connector
This section provides information on cable & connector of baseband,
power supply & monitoring to/from the external communication equipment.
2.8.1
Cable and Connector Code Necessary for Installation
Item
Goods
Code
Quantity
Remarks
1
Power
DC -48 V
GX4K80CBPD(*1)
1
(*1): Cable length
01-90: 1 to 90 m
99: 100m
When select connector, cable is
provided by the customer.
GX4K80CNPD
AC 100 to 240 V
GX4K80CBPA(*1)
GX4K80CNPA
2
ETH
GX4K80CBET(*1)
1
(*2): Cable length
01-90: 1 to 90 m
When select connector, cable is
provided by the customer and
cable type is water-proof.
3
MON
GX4K80CBAL(*1)
(1)
For monitoring use
When select connector, cable is
provided by the customer.
GX4K80CNHK
4
OPT
Ether
GX4K80CB2S(*1)
1
Select 2-SMF Ether, 1xSMF CPRI
and 2-MMF CPRI depending on
user interface.
When cable length is adjusted on
site, necessary waterproof cable
is provided by the customer
CPRI 1-core
GX4K80CB1S(*1)
CPRI 2-core
GX4K80CB2M(*1)
5
FG
GX4K80CBFG
1
M8 crimping terminal. Cable used
is provided by customer
2.8.2
Cable and Connector Description
Table 2.8.2a DC Power Cable
Connector
Equipment side
Cable Specification
Connector
External. equipment side
Waterproof, Round type, 4-Pin
4-conductor captire (0.75 mm2)
AWG14 (2.08 mm
2
)
M4 crumping terminal
Table 2.8.2b AC Power Cable
Connector
Equipment side
Cable Specification
Connector
External. equipment side
Waterproof, Round type, 3-Pin
4-conductor captire (0.75 mm
2)
AWG14 (2.08 mm
2
)
M4 crumping terminal
Table 2.8.2c Ether Electrical Cable
Connector
Equipment side
Cable Specification
Connector
External. equipment side
Waterproof, RJ-45
CAT5E with shield
RJ-45
Summary of Contents for BroadOne GX4000 R3.0 Series