REPLACEMENT PARTS
09-10
Model : AO*S24LDC
PROCESS
REGULATIONS
Like figure 1, assemble PWAB ASSY (CAPACITOR) to the SPACER
Pay attention to direction of the PWAB ASSY, when assembling PWB ASSY
(Have the wire with the terminal (white W12, purple W13) on the REACTOR side.)
Do the twist work with the following combination. (Twist it 1 time is to twist 360 .)
white W12
blue W7
purple W13
yellow W8
Like figure 2, wire lead wire. Insert TERMINAL in CONTACT certainly.
Be sure to fasten by WIRE CLAMPER after wiring.
Fit the wire in the groove firmly.
Fasten the wire with BINDER M.
three times
Assemble PWB ASSY(CAPACITOR) and Wiring
PWB ASSY (K05DG CAPACITOR)
BINDER M
Figure 1
PWB ASSY(CAPACITOR)
SPACER
BINDER M
REACTOR
Either will do, because
there is no polarity
WIRE CLAMPER
six times
60~70mm
1
2
1
2
Summary of Contents for B24LDC
Page 4: ...1 SPECIFICATIONS R410A WALL MOUNTED type INVERTER ...
Page 7: ...2 DIMENSIONS R410A WALL MOUNTED type INVERTER ...
Page 9: ...3 REFRIGERANT SYSTEM DIAGRAM R410A WALL MOUNTED type INVERTER ...
Page 11: ...4 CIRCUIT DIAGRAM R410A WALL MOUNTED type INVERTER ...
Page 13: ...5 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 34: ...6 REFRIGERANT CAUTION R410A R410A WALL MOUNTED type INVERTER ...
Page 64: ...9 REPLACEMENT PARTS R410A WALL MOUNTED type INVERTER ...
Page 65: ...REPLACEMENT PARTS Models AS B24LDC INDOOR UNIT 09 01 ...
Page 66: ......
Page 67: ......
Page 68: ...REPLACEMENT PARTS 09 04 Models AS B24LDC ...
Page 69: ...REPLACEMENT PARTS 09 05 Model AO S24LDC ...
Page 70: ......
Page 88: ...10 INSTALLATION MANUAL R410A WALL MOUNTED type INVERTER ...
Page 91: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan GS20032006 FEB 2006 Printed in Japan ...