REPLACEMENT PARTS
09-07
Model : AO*S24LDC
PROCESS
Wiring HEAT SINK
SUB ASSY
REGULATIONS
Do the twist work with the following
combination.
(Twist it 1 time is to twist 360 .)
red (W16)
black(W17) two times. (Width of twist.30~40mm)
Connect a wire (red) with terminal to +POLE of ACTPM
Connect a wire (black) with terminal to -POLE of ACTPM
+POLE
ACTPM
ACTPM
-POLE
ACTPM
IPM PWB
Pay attention the
Direction of
installation
Width of twist 30~40mm