3.  NAME OF PARTS

 

CAUTION

For appropriate signal transmission between the remote 

controller and the indoor unit, keep the signal receiver 

away from the following items:

 - Direct sunlight or other strong lights

 - Flat-panel television screen

In rooms with instantaneous fluorescent lights, such as 

inverter type ones, the signal may not be transmitted 

properly. In such a case, consult the store of purchase.

For Basic operations  ..................... Refer to page 5.

Starts or stops the air conditioner operation.

Changes the operation mode. 

 

Adjusts the setting temperature.

 

For Outdoor Unit Low Noise operation

  ... Refer to page 7.

Activates or deactivates the Outdoor Unit Low 

Noise operation.

 

Remote controller display

In this section, all the possible indicators are displayed for description. 

In actual operation, the display is linked with the button operation, and 

only shows the necessary indicators for each setting.

Signal transmitter

Aim at the signal receiver of the indoor unit properly. 

• Operating range is approximately 7 m.

• [ 

 ] will appear when the signal is transmitted.

• 

The indoor unit will emit a beep when it receive the signal 

properly. If there is no beep, press the button again.

3.1.  Indoor unit

Remote controller 

signal receiver

Horizontal airflow 

direction louvers

For Manual Auto operation  

and Filter indicator reset

(Refer to page 15.)

Rating label

Drain hose

Indicator lamps 

*2)

Front panel

Air filter

WLAN adapter slot

Intake grille 

*1)

Air cleaning filter

*1) Before starting operation, make sure that the intake grille is closed 

completely. Incomplete closing may affect the proper function or 

performance of the product.

*2)  Indicator lamps light in the following conditions. It cannot see when 

the indicator lamp is off.

Name

Color

Operation or condition

Operation

Green

Normal operation

Timer

Orange

Timer operation

Economy

Green

Economy operation 

10 °C Heat operation

WLAN

Orange

WLAN control is active.

3.2.  Remote controller

When you use the optional remote controller, the appearance 

and the operation procedure may differ.

For details, please refer to the operation manual of each remote 

controller.

 

: The setting must be done while the setting screen is displayed 

for each function.

: The button is controllable only when the air conditioner is 

operating.

:

The instruction is relating to the WLAN control.

For Energy saving operation  ........ Refer to page 7.

Activates or deactivates the Economy 

operation.

Battery loading and remote controller preparation 

(R03/LR03/AAA x 2)

5
7

6

4

8

1

2

3

1

~

3

 

Put batteries as shown in the figure above.

4

   Press 

 to start clock setting.

5

    Press 

(

)

 to set day of the week (Monday 

to Sunday). 

* By pressing 

, the time indicator can be 

changed from a 24-hour to a 12-hour clock.

6

    Press 

 to continue.

7

    Press 

(

)

 to set the clock.

Press the buttons to change the clock by a minute. 

Press down the buttons to change the clock by 10 minutes.

8

    Press 

 to complete the setting.

Be close to the indoor unit. If you press the button from a 

distance, settings may not be properly sent.

NOTES:

• 

Use specified type of batteries only. 

• 

Do not mix different types or new and used batteries together.

• Batteries can be used about 1 year in ordinary use.

•  If the remote control range noticeably shortens, replace the 

batteries, and press 

 as shown in page 4.

Do not press this button in normal use.

It starts the test run (for use by authorized service personnel only).

NOTES:

 

If the test run starts unintentionally, press   to quit the test 

run.

For 10 °C Heat operation  .............. Refer to page 7.

Activates the 10 °C Heat operation.

9387858068-01_OM.indb   3

07-Oct-20   14:00:34

Summary of Contents for ASYG09KMCDN

Page 1: ...znać się z instrukcjami i zachować niniejszy dokument do użytku w przyszłości Polski EKSPLOATACIJOS VADOVAS ORO KONDICIONIERIUS Sieninis tipas Prieš naudodamiesi šiuo gaminiu atidžiai perskaitykite šias instrukcijas ir pasilikite šį vadovą kad galėtumėte pasinaudoti ateityje Lietuvių KASUTUSJUHEND ÕHUKONDITSIONEER Seinale paigaldatav Lugege enne toote kasutamist juhised läbi ja säilitage juhend tu...

Page 2: ...re is danger of suffocation if children play with the original plastic bags Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port or inl...

Page 3: ...tional or regional regulations During transportation or relocation of the indoor unit pipes shall be covered with the wall hook bracket for protection Do not move this product by holding the indoor unit pipes The stress applied to the pipe joints may cause the flammable gas to leak during operation Do not install the unit in area filled with mineral oil such as a factory or area containing a large...

Page 4: ... following conditions It cannot see when the indicator lamp is off Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation WLAN Orange WLAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to th...

Page 5: ...the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Slee...

Page 6: ...he On timer and Off timer Sleep timer Supports your comfortable sleep by moderating the air conditioner operation gradually 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperatur...

Page 7: ...f operations cannot be set automatically If you set the On timer and Off timer on the same time the On timer will work If two On timers are set on the same time the air conditioner will run in the order of the program number You cannot the Weekly timer and the other timers simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly...

Page 8: ...ng operations are set they will start after the Powerful operation finishes Outdoor Unit Low Noise operation Energy Saving program If the wired remote controller optional is connected this function is restricted 8 2 Outdoor Unit Low Noise operation The Outdoor Unit Low Noise operation lowers noise from the outdoor unit During this operation the rotation number of the compressor decreases and the o...

Page 9: ...this product when there are people in the room who are not able to control the temperature by themselves For example infants children those with physical disabilities elderly or sick persons Fully understand the reserved timer settings and other operations before using this product Unexpected operation of the air conditioner may cause deterioration in a person s physical condition or an adverse ef...

Page 10: ...environments Radio waves may not reach or may be interrupted in the following situations Use in buildings made from concrete rebars or metal Installation near obstacles Interference with wireless communication equipment using the same frequency Places where there are magnetic fields from equipment such as microwave ovens or static electricity or radio wave interference occurs Install and setup thi...

Page 11: ...egister the air conditioner by using the mobile app Refer to the operation manual of the mobile app for details Initialization of the WLAN adapter NOTES If you do not press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote control...

Page 12: ...r conditioner If the filter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Ai...

Page 13: ...ter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a hor...

Page 14: ...nder the conditions except the permissible temperature range the air conditioner operation may stop because of the automatic protection circuit working Depending on the operating conditions the heat exchanger may freeze causing water leakage or other malfunction in the Cooling or Dry mode Other information Do not use the air conditioner for any purpose other than room cooling dry room heating or f...

Page 15: ...mitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensation formed with sudden cooling process In the Heating mode Is indicator on the indoor unit blinking In this case steam may rise from the outdoor unit because of the Automatic defrosting operation Refer to page 13 Outdoor unit emits water In the Heating mode The outdoor unit may emit water gener ated by the Aut...

Page 16: ...to the wireless router is on There is a possibility that the WLAN adapter is not properly connected to the wireless router 7 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the WLAN adapter is being updated During the air conditioner registration pairing of WLAN adapter 9 Restricted function 13 Manual Auto operation and Filter indicator re...

Reviews: