background image

En-9

NOTES:

• 

This device complies with Part 15 of FCC Rules and Industry 

Canada license-exempt RSS standard(s). 

Operation is subject to the following two conditions: 

(1)  this device may not cause interference, and

(2)  this device must accept any interference, including interference 

that may cause undesired operation of this device.

  (UTY-TFSXF1 (AP-WF1E) and UTY-TFSXG1 (AP-WG1E) models 

conform to IC (Industry Canada) standard.)

• 

This equipment has been tested and found to comply with the limits 

for a Class B digital device, pursuant to part 15 of the FCC Rules.

 

● Do not use this product in the following locations. Using 

this product in such locations may cause communications 

becoming unstable or not possible.

• 

Near wireless communication equipment that uses the 

same frequency band (2.4GHz) as this product.

• 

Places where there are magnetic fields from equipment 

such as microwave ovens, or static electricity or radio wave 

interference occurs. 

(Radio waves may not reach depending on the 

environment.)

 

Personal Information (Security-related) Usage 

Precautions

 

● There is a possibility of interception if you use wireless LAN 

equipment due to the use of radio waves regardless of 

whether you use encryption or not.

 

● Wireless LAN uses radio waves to exchange information 

between this product and the wireless router. This means 

it has the advantage of freely being able to make a LAN 

connection if within reach of radio waves. On the other hand, 

if the radio waves are within a certain range, they will reach 

all locations beyond obstacles (e.g. walls). Therefore, it is 

possible your communications may be intercepted and read 

or illegally intruded upon.

 

● Do not connect to equipment and networks which you are not 

authorized to use when setting up your wireless connection.

 

● Initialize the settings of this product when disposing it, or 

transferring it to a third party.

 

Others

 

● Use this product as regular wireless LAN equipment.

• 

Do not use this product in hospitals or in/near locations with 

medical equipment.

• 

Do not use this product within aircraft.

•  Do not use this product near electronic equipment that 

handles high-precision control or weak signals.

  Examples of electronic equipment to be careful of:

 

Hearing aids, pacemakers, fire alarms, automatic doors and 

other automatic control equipment

 

● This is not a guarantee of wireless connection and 

performance with all wireless routers and in all residential 

environments. Radio waves may not reach or may be 

interrupted in the following situations.

•  Use in buildings made from concrete, rebars or metal

•  Installation near obstacles

• 

Interference with wireless communication equipment using 

the same frequency

• 

Places where there are magnetic fields from equipment 

such as microwave ovens, or static electricity or radio wave 

interference occurs

 

Install and setup this product only after reading the operating 

manual of the wireless router.

9.2.  Setting to use WLAN control

Step 1. Application software installation

1. 

Open “Google Play” or “App Store” depending on the type 

of your smartphone or tablet PC.

2. 

Search for “FGLair”.

3. 

Install the application software (mobile app) following the 

instructions on your screen.

Step 2. User registration

1. 

Open the installed mobile app. 

2. 

Register the user (with either a smartphone or tablet PC) 

by following the instructions in the create an account 

section of the mobile app.

Step 3. Air conditioner registration (pairing of WLAN 

adapter)

NOTES:

• 

Before starting this setting, reconnect the power supply of the air 

conditioner and wait for 60 seconds or more.

• 

Check that the smartphone or tablet PC is linked to the wireless 

router you are connecting the air conditioner. The setting will not 

work if it is not connected to the same wireless router.

• 

To control 2 or more air conditioners with the same smartphone or 

tablet PC, repeat the setup of the chosen mode.

 

)

Register the air conditioner by following the instructions in 

the online manual on FUJITSU GENERAL web site.

www.fujitsu-general.com/global/support/

This operation manual describes only the setting procedure of the 

remote controller.

<How to access the online manual>

1. 

Sign in to the mobile app.

2. 

Open the side menu of the mobile app then tap [Help].

3. 

Tap [WLAN Support].

When the registration is completed, [ 

 ] indicator on the indoor unit 

will turn on.

<Manual mode>

Setting procedure of the remote controller

NOTES:  

If you do not press any buttons of the remote controller for  

60 seconds, the remote controller display will return to the 

original display.

1. 

Press   until only the clock is displayed 

on the remote controller display.

2. 

Press down 

 on the remote controller 

for more than 5 seconds.

 will be displayed on the remote controller 

display.

3. 

Press   .

4. 

Select   using 

 on the remote 

controller.

5. 

Press   .

The indoor unit enters Manual mode and [ 

 ] 

indicator on the indoor unit will blink.

NOTES:

 If the registration is not be finished in several minutes, 

Manual mode is canceled and [ 

 ] indicator turns off. 

 

In this case, please repeat the remote controller setting.

For reference

9387858068-01_OM.indb   9

07-Oct-20   14:00:41

Summary of Contents for ASYG09KMCDN

Page 1: ...znać się z instrukcjami i zachować niniejszy dokument do użytku w przyszłości Polski EKSPLOATACIJOS VADOVAS ORO KONDICIONIERIUS Sieninis tipas Prieš naudodamiesi šiuo gaminiu atidžiai perskaitykite šias instrukcijas ir pasilikite šį vadovą kad galėtumėte pasinaudoti ateityje Lietuvių KASUTUSJUHEND ÕHUKONDITSIONEER Seinale paigaldatav Lugege enne toote kasutamist juhised läbi ja säilitage juhend tu...

Page 2: ...re is danger of suffocation if children play with the original plastic bags Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port or inl...

Page 3: ...tional or regional regulations During transportation or relocation of the indoor unit pipes shall be covered with the wall hook bracket for protection Do not move this product by holding the indoor unit pipes The stress applied to the pipe joints may cause the flammable gas to leak during operation Do not install the unit in area filled with mineral oil such as a factory or area containing a large...

Page 4: ... following conditions It cannot see when the indicator lamp is off Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation WLAN Orange WLAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to th...

Page 5: ...the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Slee...

Page 6: ...he On timer and Off timer Sleep timer Supports your comfortable sleep by moderating the air conditioner operation gradually 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperatur...

Page 7: ...f operations cannot be set automatically If you set the On timer and Off timer on the same time the On timer will work If two On timers are set on the same time the air conditioner will run in the order of the program number You cannot the Weekly timer and the other timers simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly...

Page 8: ...ng operations are set they will start after the Powerful operation finishes Outdoor Unit Low Noise operation Energy Saving program If the wired remote controller optional is connected this function is restricted 8 2 Outdoor Unit Low Noise operation The Outdoor Unit Low Noise operation lowers noise from the outdoor unit During this operation the rotation number of the compressor decreases and the o...

Page 9: ...this product when there are people in the room who are not able to control the temperature by themselves For example infants children those with physical disabilities elderly or sick persons Fully understand the reserved timer settings and other operations before using this product Unexpected operation of the air conditioner may cause deterioration in a person s physical condition or an adverse ef...

Page 10: ...environments Radio waves may not reach or may be interrupted in the following situations Use in buildings made from concrete rebars or metal Installation near obstacles Interference with wireless communication equipment using the same frequency Places where there are magnetic fields from equipment such as microwave ovens or static electricity or radio wave interference occurs Install and setup thi...

Page 11: ...egister the air conditioner by using the mobile app Refer to the operation manual of the mobile app for details Initialization of the WLAN adapter NOTES If you do not press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote control...

Page 12: ...r conditioner If the filter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Ai...

Page 13: ...ter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a hor...

Page 14: ...nder the conditions except the permissible temperature range the air conditioner operation may stop because of the automatic protection circuit working Depending on the operating conditions the heat exchanger may freeze causing water leakage or other malfunction in the Cooling or Dry mode Other information Do not use the air conditioner for any purpose other than room cooling dry room heating or f...

Page 15: ...mitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensation formed with sudden cooling process In the Heating mode Is indicator on the indoor unit blinking In this case steam may rise from the outdoor unit because of the Automatic defrosting operation Refer to page 13 Outdoor unit emits water In the Heating mode The outdoor unit may emit water gener ated by the Aut...

Page 16: ...to the wireless router is on There is a possibility that the WLAN adapter is not properly connected to the wireless router 7 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the WLAN adapter is being updated During the air conditioner registration pairing of WLAN adapter 9 Restricted function 13 Manual Auto operation and Filter indicator re...

Reviews: