background image

En-13

12. GENERAL  INFORMATION

 

Heating performance

This air conditioner operates on the heat-pump principle, absorbing 

heat from air outdoors and transferring that heat to the indoor unit. As a 

result, the operating performance is reduced as outdoor air temperature 

drops.

If you feel that the heating performance is insufficient, we recommend 

you to use this air conditioner in conjunction with other kinds of heating 

appliance.

 

Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost may 

form on the outdoor unit during the heating operation, and it could 

reduce the operating performance of the product. 
For frost protection, a microcomputer-controlled automatic defrost 

function is equipped in this air conditioner. 

If frost forms, the air conditioner will temporarily stop, and defrost circuit 

will operate briefly (maximum of 15 minutes.)

[  ] indicator on the indoor unit blinks during this operation. 
If frost forms on the outdoor unit after the Heating operation, the outdoor 

unit will stop automatically after it operates for a few minutes. Then the 

Automatic defrosting operation starts.

 

Auto-restart function

In event of power interruption such as a blackout, the air conditioner 

stops once. But it restarts automatically and performs previous operation 

when the power supply is resumed.
If any power interruption occurs after the timer is set, counting down of 

the timer will be reset. 
After the power supply is resumed, [ 

 ] indicator on the indoor unit 

blinks to notify you that there has been a timer fault. In such a case, 

reset the clock and timer settings.

 

Malfunctions caused by other electrical 

devices

Use of other electrical appliances such as an electric shaver or nearby 

use of a wireless radio transmitter may cause the malfunction of the air 

conditioner. 

If you encounter such a malfunction, turn off the circuit breaker once. 

Then turn it on again, and resume operation by using the remote 

controller.

 

Indoor unit temperature and humidity range

Permissible ranges of temperature and humidity are as follows:

Indoor temperature

Cooling/Dry 

[°C]

18 to 32

Heating

[°C]

16 to 30

Indoor humidity

[%]

80 or less *

1)

*1) If the air conditioner is used continuously for many hours, water may 

condense on the surface and drip.

•  If the unit is operated under the conditions except the permissible 

temperature range, the air conditioner operation may stop because 

of the automatic protection circuit working.

•  Depending on the operating conditions, the heat exchanger may 

freeze, causing water leakage or other malfunction (in the Cooling 

or Dry mode).

 

Other information

•  Do not use the air conditioner for any purpose other than room 

cooling/dry, room heating or fan.

•  For the permissible ranges of temperature and humidity for the 

outdoor unit, refer to the outdoor unit installation manual.

13. OPTIONAL  PARTS

13.1. Wired remote controller

The optional wired remote controller can be used.

You can use wired and wireless remote controller together.

However, some functions of the wireless remote controller are restricted. 

If you set the restricted functions, beeping sound will be heard, [ 

 ], [   ], 

and [ 

 ] indicator on the indoor unit will blink.

<Restricted functions for wireless remote controller>
When using together with wired remote controller (2-wired type)

• 

Powerful operation

• 

Outdoor Unit Low Noise operation

•  10 °C Heat operation

You can use wired remote controller and wireless LAN control.

However, some operations  from the mobile app are restricted.

Multiple remote controller

You can connect two wired remote controllers to one air conditioner. 

Either remote controller can control the air conditioner.

However, the timer functions cannot be used by the secondary unit.

13.2. Group control

One remote controller can control up to 16 air conditioners. All of the air 

conditioners will be operated with the same settings.

You cannot use group control and WLAN control together.

14. TROUBLESHOOTING

 WARNING

In the following events, immediately stop operation of 

the air conditioner, and disconnect all the power supply 

by turning off the electrical breaker or disconnecting 

the power plug. Then consult your dealer or authorized 

service personnel.

As long as the unit is connected to the power supply, it 

is not insulated from the power supply even if the unit is 

turned off.

•  Unit smells of something burning or emits smoke

•  Water leaks from the unit

Does not operate at all.

 

Has there been a power outage? 

 

In this case, the unit restarts automatically after the power supply 

is resumed. (Refer to 

page 13

.)

 

Has the circuit breaker been turned off? 

 

⇒ 

Turn on the circuit breaker.

 

Has a fuse blown out or the circuit breaker been tripped?

 

⇒ 

Replace the fuse or reset the circuit breaker.

 

Is the timer operating?

 

 To check or deactivate the timer setting, refer to 

page 5

.

9387858068-01_OM.indb   13

07-Oct-20   14:00:44

Summary of Contents for ASYG09KMCDN

Page 1: ...znać się z instrukcjami i zachować niniejszy dokument do użytku w przyszłości Polski EKSPLOATACIJOS VADOVAS ORO KONDICIONIERIUS Sieninis tipas Prieš naudodamiesi šiuo gaminiu atidžiai perskaitykite šias instrukcijas ir pasilikite šį vadovą kad galėtumėte pasinaudoti ateityje Lietuvių KASUTUSJUHEND ÕHUKONDITSIONEER Seinale paigaldatav Lugege enne toote kasutamist juhised läbi ja säilitage juhend tu...

Page 2: ...re is danger of suffocation if children play with the original plastic bags Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port or inl...

Page 3: ...tional or regional regulations During transportation or relocation of the indoor unit pipes shall be covered with the wall hook bracket for protection Do not move this product by holding the indoor unit pipes The stress applied to the pipe joints may cause the flammable gas to leak during operation Do not install the unit in area filled with mineral oil such as a factory or area containing a large...

Page 4: ... following conditions It cannot see when the indicator lamp is off Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation WLAN Orange WLAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to th...

Page 5: ...the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Slee...

Page 6: ...he On timer and Off timer Sleep timer Supports your comfortable sleep by moderating the air conditioner operation gradually 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperatur...

Page 7: ...f operations cannot be set automatically If you set the On timer and Off timer on the same time the On timer will work If two On timers are set on the same time the air conditioner will run in the order of the program number You cannot the Weekly timer and the other timers simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly...

Page 8: ...ng operations are set they will start after the Powerful operation finishes Outdoor Unit Low Noise operation Energy Saving program If the wired remote controller optional is connected this function is restricted 8 2 Outdoor Unit Low Noise operation The Outdoor Unit Low Noise operation lowers noise from the outdoor unit During this operation the rotation number of the compressor decreases and the o...

Page 9: ...this product when there are people in the room who are not able to control the temperature by themselves For example infants children those with physical disabilities elderly or sick persons Fully understand the reserved timer settings and other operations before using this product Unexpected operation of the air conditioner may cause deterioration in a person s physical condition or an adverse ef...

Page 10: ...environments Radio waves may not reach or may be interrupted in the following situations Use in buildings made from concrete rebars or metal Installation near obstacles Interference with wireless communication equipment using the same frequency Places where there are magnetic fields from equipment such as microwave ovens or static electricity or radio wave interference occurs Install and setup thi...

Page 11: ...egister the air conditioner by using the mobile app Refer to the operation manual of the mobile app for details Initialization of the WLAN adapter NOTES If you do not press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote control...

Page 12: ...r conditioner If the filter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Ai...

Page 13: ...ter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a hor...

Page 14: ...nder the conditions except the permissible temperature range the air conditioner operation may stop because of the automatic protection circuit working Depending on the operating conditions the heat exchanger may freeze causing water leakage or other malfunction in the Cooling or Dry mode Other information Do not use the air conditioner for any purpose other than room cooling dry room heating or f...

Page 15: ...mitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensation formed with sudden cooling process In the Heating mode Is indicator on the indoor unit blinking In this case steam may rise from the outdoor unit because of the Automatic defrosting operation Refer to page 13 Outdoor unit emits water In the Heating mode The outdoor unit may emit water gener ated by the Aut...

Page 16: ...to the wireless router is on There is a possibility that the WLAN adapter is not properly connected to the wireless router 7 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the WLAN adapter is being updated During the air conditioner registration pairing of WLAN adapter 9 Restricted function 13 Manual Auto operation and Filter indicator re...

Reviews: