background image

En-11

10. SETTINGS ON INSTALLATION

10.1. Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can 

specify the air conditioner which the remote controller controls.
When two or more air conditioners are in the room and you wish to 

operate them separately, set the custom code (4 selections possible).

NOTES: 

If custom codes is different between the indoor unit and the 

remote controller, the indoor unit cannot receive a signal from 

the remote controller.

How to set the remote controller custom code

1. 

 Press 

 until only the clock is displayed on the remote 

controller display.

2. 

 Press and hold

 

 

for more than 

5 seconds.

The current custom code will be 

displayed (initially set to A).

3. 

Press 

 to change the 

custom code between A↔B↔C↔D 

(

).

* Match the custom code on the display 

to the air conditioner custom code.

4. 

Press 

 again.

The custom code will be set. 

 

The display  will return to the clock display.

•  To change the air conditioner custom code, contact an authorized 

service personnel (initially set to A).

•   If you do not press any buttons for 30 seconds after the custom 

code is displayed, the display returns to the clock display. In this 

case, repeat the setting from step 2.

•  Depending on the remote controller, the custom code may return 

to A when replacing the batteries. In this case, reset the custom 

code as necessary. If you do not know the air conditioner custom 

code, try each code until you find the code which operates the air 

conditioner.

11. CLEANING AND  CARE

 

CAUTION

• 

Before cleaning this product, be sure to turn it off and 

disconnect all the power supply. 

•  Before starting operation, make sure that the intake 

grille has been shut completely. Incomplete closing 

of the intake grille might have an effect on the proper 

working or performance of the air conditioner.

• 

If the filter cleaning involves high-place work, please 

consult the authorized service

 

personnel.

• 

Do not touch the aluminum fins of heat exchanger 

built-in the indoor unit to avoid personal injury when 

you  maintain the unit.

•  Do not expose the indoor unit to liquid insecticides or 

hair sprays.

•  Do not stand on slippery, uneven or unstable surfaces 

when you maintain the unit.

Intake grille

Air filters

Indoor unit body

Air cleaning filters

(Apple catechin filter, Ion deodorization filter)

The frequency of the cleaning is as shown in the following table.

What to do

Frequency

Cleaning indoor unit body

When you notice

Cleaning air filter

Every 2 weeks

Cleaning Ion deodorization filter

Every 3 months

Replacing Apple-catechin filter

(Model name: UTR-FA16)
Replacing Ion deodorization filter

(Model name: UTR-FA16-2)

Every 3 years

* The air cleaning filters are sold separately. When you replace them, 

please contact the store of purchase.

Cleaning indoor unit body

NOTES:

• 

Do not use water hotter than 40 °C.

•  Do not use scouring cleanser, volatile solvents such as benzene or 

thinner.

1. 

Wipe the indoor unit body gently with a soft cloth moisten 

with warm water.

2. 

Wipe the indoor unit body gently with a dry and soft cloth.

Cleaning air filter

1. 

Open the intake grille until it snaps.

2. 

Remove the air filters.

Lift up the air filters' handle, disconnect the two lower tabs, and pull 

out.

Air Filter handle

Tabs (2 places)

3. 

Remove the dust in either of the following ways.

• 

Cleaning with vacuum cleaner.

• 

Washing with mild detergent and warm water. After washing, dry the 

air filters thoroughly in shade.

4. 

Replace the air filters.

Align the sides of the air filter with the panel, and push in fully. 

Make sure to the two lower tabs are returned to their holes in the 

indoor unit properly.

5. 

Close the intake grille. 

Press 4 places on the intake grille to close it completely.

NOTES: 

If dirt accumulates on the air filter, airflow will be reduced, 

operating  efficiency will lower, and the noise will increase.

9387858068-01_OM.indb   11

07-Oct-20   14:00:43

Summary of Contents for ASYG09KMCDN

Page 1: ...znać się z instrukcjami i zachować niniejszy dokument do użytku w przyszłości Polski EKSPLOATACIJOS VADOVAS ORO KONDICIONIERIUS Sieninis tipas Prieš naudodamiesi šiuo gaminiu atidžiai perskaitykite šias instrukcijas ir pasilikite šį vadovą kad galėtumėte pasinaudoti ateityje Lietuvių KASUTUSJUHEND ÕHUKONDITSIONEER Seinale paigaldatav Lugege enne toote kasutamist juhised läbi ja säilitage juhend tu...

Page 2: ...re is danger of suffocation if children play with the original plastic bags Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port or inl...

Page 3: ...tional or regional regulations During transportation or relocation of the indoor unit pipes shall be covered with the wall hook bracket for protection Do not move this product by holding the indoor unit pipes The stress applied to the pipe joints may cause the flammable gas to leak during operation Do not install the unit in area filled with mineral oil such as a factory or area containing a large...

Page 4: ... following conditions It cannot see when the indicator lamp is off Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation WLAN Orange WLAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to th...

Page 5: ...the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Slee...

Page 6: ...he On timer and Off timer Sleep timer Supports your comfortable sleep by moderating the air conditioner operation gradually 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperatur...

Page 7: ...f operations cannot be set automatically If you set the On timer and Off timer on the same time the On timer will work If two On timers are set on the same time the air conditioner will run in the order of the program number You cannot the Weekly timer and the other timers simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly...

Page 8: ...ng operations are set they will start after the Powerful operation finishes Outdoor Unit Low Noise operation Energy Saving program If the wired remote controller optional is connected this function is restricted 8 2 Outdoor Unit Low Noise operation The Outdoor Unit Low Noise operation lowers noise from the outdoor unit During this operation the rotation number of the compressor decreases and the o...

Page 9: ...this product when there are people in the room who are not able to control the temperature by themselves For example infants children those with physical disabilities elderly or sick persons Fully understand the reserved timer settings and other operations before using this product Unexpected operation of the air conditioner may cause deterioration in a person s physical condition or an adverse ef...

Page 10: ...environments Radio waves may not reach or may be interrupted in the following situations Use in buildings made from concrete rebars or metal Installation near obstacles Interference with wireless communication equipment using the same frequency Places where there are magnetic fields from equipment such as microwave ovens or static electricity or radio wave interference occurs Install and setup thi...

Page 11: ...egister the air conditioner by using the mobile app Refer to the operation manual of the mobile app for details Initialization of the WLAN adapter NOTES If you do not press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote control...

Page 12: ...r conditioner If the filter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Ai...

Page 13: ...ter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a hor...

Page 14: ...nder the conditions except the permissible temperature range the air conditioner operation may stop because of the automatic protection circuit working Depending on the operating conditions the heat exchanger may freeze causing water leakage or other malfunction in the Cooling or Dry mode Other information Do not use the air conditioner for any purpose other than room cooling dry room heating or f...

Page 15: ...mitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensation formed with sudden cooling process In the Heating mode Is indicator on the indoor unit blinking In this case steam may rise from the outdoor unit because of the Automatic defrosting operation Refer to page 13 Outdoor unit emits water In the Heating mode The outdoor unit may emit water gener ated by the Aut...

Page 16: ...to the wireless router is on There is a possibility that the WLAN adapter is not properly connected to the wireless router 7 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the WLAN adapter is being updated During the air conditioner registration pairing of WLAN adapter 9 Restricted function 13 Manual Auto operation and Filter indicator re...