background image

En-12

Cleaning Ion deodorization filter and

 

Replacing Apple-catechin filter

1. 

Remove the air filters. Refer to steps 1 ~ 2

 

of “Cleaning air 

filter”.

2. 

Remove the air cleaning filters from the air cleaning filter 

holder.

Air cleaning filter

Air cleaning filter frame

3. 

Flush the Ion deodorization filter (light blue) with high-

pressure hot water until the surface of the filters are covered 

with water.

4. 

Wash the Ion deodorization filter with diluent neutral 

detergent.

Do not ream or rub, otherwise the deodorizing effect may decrease.

5. 

Rinse the Ion deodorization filter with water flow.

6. 

Dry the Ion deodorization filter in shade.

7. 

Remove the Apple-catechin filter (light green) from the air 

cleaning filter holder.

8. 

Set the new or washed air cleaning filters into the air 

cleaning filter frames.

NOTES: 

Use the Apple-catechin filter as soon as possible after opening 

the package. The air cleaning effect decreases when the filters 

are left in the opened package.

9. 

Install the air cleaning filter holders to the air filters.

Engage the 4 hooks at the rear of the air cleaning filter frame with 

the latch at both ends of the air filter.

 

* Take care that the air cleaning filter does not project beyond the 

frame.

Hook (4 places at the rear)

Latch (4 places)

NOTES: 

Take care that the air cleaning filter does not project 

beyond the frame.

10. 

Replace the air filters and close the intake grille. Refer to 

steps 4 ~ 5 of “Cleaning air filter”.

Replacing Ion deodorization filter

1. 

Remove the air filters. Refer to steps 1 ~ 2

 

of “Cleaning air 

filter”.

2. 

Remove the Ion deodorization filter (light blue) from the air 

cleaning filter holder.

3. 

Install the new Ion deodorizing filter.

Removing and installing intake grille

 

Removing intake grille

1. 

Open the intake grille until it snaps.

2. 

Pull the mounting shafts while keeping the intake grille in a 

horizontal position.

 

Installing intake grille

1. 

While holding the intake grille horizontal, set the left and 

right mounting shafts into the pillow blocks at the top of the 

front panel. 

Insert the shaft until it snaps to latch each shaft properly.

2. 

Close the intake grille.

3. 

Press 4 places on the intake grille to close it completely.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 

Fan mode operation for half a day to dry the internal parts thoroughly 

before the normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 

reduce the performance even if you have maintained the unit properly.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.

Filter indicator reset (Special setting)

This function can be used if set correctly during installation. Please 

consult authorized service personnel in order to use this function.

)

)

Clean the air filter when the indicator lamp show the 

following:

Indicator lamp

Blinking pattern

   

Blinks 3 times, at intervals of 21 seconds

After cleaning, reset the filter indicator by pushing

 

 on the 

indoor unit for 2 seconds or less.

9387858068-01_OM.indb   12

07-Oct-20   14:00:44

Summary of Contents for ASYG09KMCDN

Page 1: ...znać się z instrukcjami i zachować niniejszy dokument do użytku w przyszłości Polski EKSPLOATACIJOS VADOVAS ORO KONDICIONIERIUS Sieninis tipas Prieš naudodamiesi šiuo gaminiu atidžiai perskaitykite šias instrukcijas ir pasilikite šį vadovą kad galėtumėte pasinaudoti ateityje Lietuvių KASUTUSJUHEND ÕHUKONDITSIONEER Seinale paigaldatav Lugege enne toote kasutamist juhised läbi ja säilitage juhend tu...

Page 2: ...re is danger of suffocation if children play with the original plastic bags Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port or inl...

Page 3: ...tional or regional regulations During transportation or relocation of the indoor unit pipes shall be covered with the wall hook bracket for protection Do not move this product by holding the indoor unit pipes The stress applied to the pipe joints may cause the flammable gas to leak during operation Do not install the unit in area filled with mineral oil such as a factory or area containing a large...

Page 4: ... following conditions It cannot see when the indicator lamp is off Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation WLAN Orange WLAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to th...

Page 5: ...the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Slee...

Page 6: ...he On timer and Off timer Sleep timer Supports your comfortable sleep by moderating the air conditioner operation gradually 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperatur...

Page 7: ...f operations cannot be set automatically If you set the On timer and Off timer on the same time the On timer will work If two On timers are set on the same time the air conditioner will run in the order of the program number You cannot the Weekly timer and the other timers simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly...

Page 8: ...ng operations are set they will start after the Powerful operation finishes Outdoor Unit Low Noise operation Energy Saving program If the wired remote controller optional is connected this function is restricted 8 2 Outdoor Unit Low Noise operation The Outdoor Unit Low Noise operation lowers noise from the outdoor unit During this operation the rotation number of the compressor decreases and the o...

Page 9: ...this product when there are people in the room who are not able to control the temperature by themselves For example infants children those with physical disabilities elderly or sick persons Fully understand the reserved timer settings and other operations before using this product Unexpected operation of the air conditioner may cause deterioration in a person s physical condition or an adverse ef...

Page 10: ...environments Radio waves may not reach or may be interrupted in the following situations Use in buildings made from concrete rebars or metal Installation near obstacles Interference with wireless communication equipment using the same frequency Places where there are magnetic fields from equipment such as microwave ovens or static electricity or radio wave interference occurs Install and setup thi...

Page 11: ...egister the air conditioner by using the mobile app Refer to the operation manual of the mobile app for details Initialization of the WLAN adapter NOTES If you do not press any buttons of the remote controller for 60 seconds the remote controller display will return to the original display 1 Press until only the clock is displayed on the remote controller display 2 Press down on the remote control...

Page 12: ...r conditioner If the filter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Ai...

Page 13: ...ter Replacing Ion deodorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a hor...

Page 14: ...nder the conditions except the permissible temperature range the air conditioner operation may stop because of the automatic protection circuit working Depending on the operating conditions the heat exchanger may freeze causing water leakage or other malfunction in the Cooling or Dry mode Other information Do not use the air conditioner for any purpose other than room cooling dry room heating or f...

Page 15: ...mitted from the unit In the Cooling or Dry mode A thin mist may be generated by condensation formed with sudden cooling process In the Heating mode Is indicator on the indoor unit blinking In this case steam may rise from the outdoor unit because of the Automatic defrosting operation Refer to page 13 Outdoor unit emits water In the Heating mode The outdoor unit may emit water gener ated by the Aut...

Page 16: ...to the wireless router is on There is a possibility that the WLAN adapter is not properly connected to the wireless router 7 Disconnect the power supply to the air conditioner via breaker or plug and then re connect The software of the WLAN adapter is being updated During the air conditioner registration pairing of WLAN adapter 9 Restricted function 13 Manual Auto operation and Filter indicator re...

Reviews: