En-2

Special tools for R410A

21 21 

Tool name

Contents of change

Gauge manifold

Pressure is high and cannot be measured with a conventional 

gauge. To prevent erroneous mixing of other refrigerants, the 

diameter of each port has been changed.

It is recommended the gauge with seals –0.1 to 5.3 MPa  

(-1 to 53 bar) for high pressure. –0.1 to 3.8 MPa (-1 to 38 bar) 

for low pressure.

Charge hose

To increase pressure resistance, the hose material and base 

size were changed.

Vacuum pump

A conventional vacuum pump can be used by installing a 

vacuum pump adapter.

Gas leakage 

detector

Special gas leakage detector for HFC refrigerant R410A.

Copper pipes

It is necessary to use seamless copper pipes and it is desirable that the amount of residual 

oil is less than 40 mg/10 m. Do not use copper pipes having a collapsed, deformed or 

discolored portion (especially on the interior surface). Otherwise, the expansion valve or 

capillary tube may become blocked with contaminants.

As an air conditioner using R410A incurs pressure higher than when using conventional 

refrigerant, it is necessary to choose adequate materials. 

Thicknesses of copper pipes used with R410A are as shown in the table. Never use copper 

pipes thinner than that in the table even when it is available on the market.

Thicknesses of Annealed Copper Pipes (R410A)

Pipe outside diameter

Thickness

6.35 mm (1/4 in.)

0.80 mm

9.52 mm (3/8 in.)

0.80 mm

12.70 mm (1/2 in.)

0.80 mm

15.88 mm (5/8 in.)

1.00 mm

19.05 mm (3/4 in.)

1.20 mm

Accessories

21 21 

 WARNING

For installation purposes, be sure to use the parts supplied by the manufacturer or other 

prescribed parts. The use of non-prescribed parts can cause serious accidents such as 

the unit falling, water leakage, electric shock, or fire.

Do not throw away the connecting parts until the installation has been complete.

Name and shape

Q’ty

Application

Installation  

manual

1

(This book)

Drain cap

2

For outdoor unit drain piping work 

[Heat & Cool model (Reverse cycle) 

only]

Drain pipe

1

Putty 

1

For sealing

Adapter assy 

12.7 mm / 9.52 mm

2

For use when connecting models 

7–12 to outdoor port A or B

Adapter assy 

12.7 mm / 15.88 mm

1

For use when connecting model 24

System configuration

21 41 

Layout example for the indoor units and outdoor unit.

Circuit breaker

INDOOR UNITS

UNIT D

7-12

UNIT C

7-12

UNIT B

7-18

UNIT A

7-24

OUTDOOR UNIT

Power source 

230 V ~ 50 Hz

Power cable

Connection cable

Refrigerant pipe

d

c

H1

H1

H2

b

a

CONNECTABLE INDOOR UNIT CAPACITY TYPE

21 41 11 

 CAUTION

The total capacity of the indoor units connected must be between 27,000 and 

49,000BTU.
Be sure to check the connecting pattern in technical manual when installed since 

connection pattern is specified in it. Operation cannot be guaranteed if connected by a 

method not specified in it. It can cause the fault of the product.

At least three indoor units must be connected to the outdoor unit.

To install an indoor unit, refer to the installation Manual included with the indoor unit. 

 

Outdoor port

Connectable model name

Standard port size

D

6.35/9.52

7 – 12

C

6.35/9.52

7 – 12

B

6.35/12.7

7 – 12

*1

 /14 – 18

A

6.35/12.7

7 – 12

*1

 /14 – 24

*2

*1

  When connecting models 7–12 to the outdoor unit, the included adapter is necessary.

 

(For more information, refer to “4.1.3. HOW TO USE ADAPTER”.)

*2

  When connecting model 24 to the outdoor unit, connect only two other indoor units to 

the outdoor unit. (Max indoor unit capacity connection: 24,000 + 12,000 + 12,000 BTU)

 

In addition, the included adapter is necessary to connect the indoor unit to the outdoor 

unit. (For more information, refer to “4.1.3. HOW TO USE ADAPTER”.)

UNIT D ø6.35, ø9.52

UNIT C ø6.35, ø9.52

UNIT B ø6.35, ø12.7

UNIT A ø6.35, ø12.7

LIMITATION OF REFRIGERANT PIPING LENGTH

21 41 21 

 CAUTION

The total maximum pipe lengths and height difference of this product are shown in the 

table. 

If the units are further apart than this, correct operation cannot be guaranteed.

Total max1 length (a+b+c+d)

70 m (230 ft)

*3

Max1 length for each indoor unit  

(a, b, c, or d)

25 m (82 ft)

Max1 height difference between 

outdoor unit and each indoor unit 

(H1)

15 m (49 ft)

Max1 height difference between 

indoor units (H2)

10 m (33 ft)

Min1 length for each indoor unit  

(a, b, c, or d)

5 m (16 ft)

Total min1 length (a+b+c+d)

20 m (66 ft)

*3

  If the total piping length is 51 m or longer, additional refrigerant charging is necessary. 

(For more information, refer to “6.2. Additional charging”.)

SELECTING PIPE SIZES

21 41 21 

The diameters of the connection pipes differ according to the capacity of the indoor unit.

Refer to the following table for the proper diameters of the connection pipes between the 

indoor and outdoor units.

Capacity of indoor 

unit

Gas pipe size  

(thickness) [mm]

Liquid pipe size 

(thickness) [mm]

7 – 12

ø9.52 (0.8)

ø6.35 (0.8)

14 – 18

ø12.7 (0.8)

ø6.35 (0.8)

24

ø15.88 (1.0)

ø6.35 (0.8)

 CAUTION

Operation cannot be guaranteed if the correct combination of pipes, valves, etc., is not 

used to connect the indoor and outdoor units.

9374872121-03_IM.indb   2

2/10/2555   10:07:47

Summary of Contents for aoyg30lat4

Page 1: ...AZIONE ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ MANUAL DE INSTALAÇÃO РУКОВОДСТВО ПО УСТАНОВКЕ MONTAJ KILAVUZU For authorized personnel only PART NO 9374872121 03 Nur für autorisiertes Personal Pour le personnel agréé uniquement Solo para personal autorizado Ad uso esclusivo del personale autorizzato Για εξουσιοδοτημένο προσωπικό σέρβις Apenas para técnicos autorizados Для уполномоченного персонала Yetkili servis p...

Page 2: ... all security information before use or install the air conditioner Do not attempt to install the air conditioner or a part of the air conditioner by yourself This unit must be installed by qualified personnel with a capacity certificate for handling refrigerant fluids Refer to regulation and laws in use on installation place The installation must be carried out in compliance with regulations in f...

Page 3: ...ce 230 V 50 Hz Power cable Connection cable Refrigerant pipe d c H1 H1 H2 b a CONNECTABLE INDOOR UNIT CAPACITY TYPE 222222222 CAUTION The total capacity of the indoor units connected must be between 27 000 and 49 000BTU Be sure to check the connecting pattern in technical manual when installed since connection pattern is specified in it Operation cannot be guaranteed if connected by a method not s...

Page 4: ... accumulation snow fall or freezing take appropriate measures to protect it from those elements To ensure a stable operation install inlet and outlet ducts Install the outdoor unit in a location that is away from exhaust or the vent ports that discharge vapor soot dust or debris Install the indoor unit outdoor unit power supply cable connection cable and remote controller cable at least 1 m away f...

Page 5: ...h as concrete blocks The foundation shall support the legs of the unit and have a width of 50mm or more Depending on the installation conditions the outdoor unit may spread its vibration during operation which may cause noise and vibration Therefore attach damping materials such as damping pads to the outdoor unit during installation Install the foundation making sure that there is enough space fo...

Page 6: ...63 to 75 630 to 750 19 05 3 4 dia 90 to 110 900 to 1100 HOW TO USE ADAPTER Connection ports of outdoor unit 444444444 When using the ADAPTER be careful not to overtighten the nut or the smaller pipe may be damaged Apply a coat of refrigeration oil to the threaded connection port of the outdoor unit where the flare nut comes in Use appropriate wrenches to avoid damaging the connection thread by ove...

Page 7: ...t comply with the applicable local and national code Unit wiring 555555 When stripping off the coating of a lead wire always use a special tool such as a wire stripper If there is no special tool available carefully strip the coating with a knife etc Earth Ground wire 30 mm 100 mm or more Power supply cable Earth Ground wire 15 mm 60 mm or more Connection cable How to connect wiring to the termina...

Page 8: ... it is satisfactory If a pressure decrease is confirmed there is a leak so it is necessary to specify the leak location and make minor adjustments Discharge the nitrogen gas and starting removing the gas with a vacuum pump Open the valve of the gauge manifold fully Operate the vacuum pump and start pump down Check that the compound pressure gauge reads 0 1 MPa 76 cmHg operate the vacuum pump for 3...

Page 9: ...sor error for Indoor unit D 5 times 3 way valve temp sensor error for Indoor unit A 6 times 3 way valve temp sensor error for Indoor unit B 6 times 3 way valve temp sensor error for Indoor unit C 6 times 3 way valve temp sensor error for Indoor unit D 6 times Compressor temp sensor error 7 times Heat sink temp sensor error 8 times High pressure switch 1 error 9 times High pressure switch 2 error 1...

Reviews: