1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section 

carefully before you use this product, and be sure to comply 

with the following safety precautions.
Incorrect operation due to failure to follow the instructions may 

cause harm or damage, the seriousness of which is classi

fi

 ed 

as follows:

 WARNING

This mark warns of death or serious injury.

 CAUTION

This mark warns of injury or damage to property.

This mark denotes an action that is PROHIBITED.

This mark denotes an action that is COMPULSORY.

Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this product uses a 

fl

 ammable refrigerant. If the refrigerant is leaked and 

exposed to an external ignition source, there is a risk 

of 

fi

 re.

CAUTION

This symbol shows that the operating manual should 

be read carefully.

CAUTION

This symbol shows that a service personnel should 

be handling this equipment with reference to the 

installation manual.

CAUTION

This symbol shows that information is available such 

as the operating manual or installation manual.

 WARNING

•  The appliance shall be installed, operated and stored 

in a room with a 

fl

 oor area larger than X m².

Amount of refrigerant charge

M (kg)

Minimum room area

X (m

2

)

 1.22 

-

1.22 < M 

 1.23 

1.45

1.23 < M 

 1.50 

2.15

1.50 < M 

 1.75 

2.92

1.75 < M 

 2.0 

3.82

2.0 < M 

 2.5 

5.96

2.5 < M 

 3.0 

8.59

3.0 < M 

 3.5 

11.68

3.5 < M 

 4.0 

15.26

(IEC 60335-2-40)

•  This product contains no user-serviceable parts. 

Always consult authorized service personnel for 

repairing, installation, and relocation of this product.

Improper installation or handling will cause leakage, 

electric shock, or 

fi

 re.

•  In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 

disconnect all the power supply by turning off the 

electrical breaker or disconnecting the power plug.

Then consult authorized service personnel.

•  Take care not to damage the power supply cable.

If it is damaged, it should be replaced only by 

authorized service personnel in order to avoid a 

hazard.

•  In the event of refrigerant leakage, be sure to keep 

away from 

fi

 re or any 

fl

 ammables, and consult 

authorized service personnel.

•  In the event of a thunder storm or any prior sign 

of a lightning strike, turn off the air conditioner via 

the remote controller, and refrain from touching the 

product or the power source to prevent any electrical 

hazards.

•  This product shall be stored in a room without 

continuously operating ignition sources (for example: 

open 

fl

 ames, an operating gas appliance or an 

operating electric heater).

•  This product shall be stored in a well-ventilated area.
•  Be aware that refrigerants may not contain an odour.
•  This product shall be stored so as to prevent 

mechanical damage from occurring.

•  Disposing of the product shall be done properly, in 

compliance with national or regional regulations.

•  During transportation or relocation of the indoor unit, 

pipes shall be covered with the wall hook bracket for 

protection.

Do not move this product by holding the indoor unit pipes.

(The stress applied to the pipe joints may cause the 

fl

 ammable gas to leak during operation).

Contents

1. SAFETY PRECAUTIONS 

.......................................... 1

2. PREPARATION 

......................................................... 2

3.  NAME OF PARTS ..................................................... 3

3.1. Indoor 

unit 

........................................................ 3

3.2. Remote 

controller 

............................................. 3

4. BASIC OPERATIONS 

............................................... 5

5. AIRFLOW SETTINGS 

............................................... 5

5.1.  Fan speed setting ............................................. 5
5.2. Air

fl

 ow direction setting .................................... 5

6. TIMER OPERATIONS 

............................................... 5

6.1. Weekly 

timer 

..................................................... 6

6.2.  On timer or Off timer ......................................... 6
6.3. Program 

timer 

................................................... 6

6.4.  Sleep timer  ...................................................... 6

7.  ENERGY SAVING OPERATION ............................... 7

7.1. Economy 

operation 

.......................................... 7

8. OTHER OPERATIONS 

............................................. 7

8.1. Powerful 

operation 

........................................... 7

8.2.  Outdoor Unit Low Noise operation ................... 7
8.3.  10 °C Heat operation ........................................ 7

9.  SETTINGS ON INSTALLATION ................................ 7

9.1.  Remote controller custom code setting ............ 7

10. CLEANING AND CARE ............................................. 8
11. GENERAL INFORMATION ....................................... 9
12. OPTIONAL PARTS ................................................. 10

12.1. Wired remote controller .................................. 10
12.2. Group control .................................................. 10
12.3. W-LAN control ................................................ 10
12.4. Multi-type air conditioner ................................ 12

13. TROUBLESHOOTING ............................................ 12

[Original Instructions]

00_9387858037_OM.indb   1

00_9387858037_OM.indb   1

2019/8/26   17:12:02

2019/8/26   17:12:02

Summary of Contents for AOYG12KETA

Page 1: ...er ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di utilizzare l apparecchio leggere...

Page 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Page 3: ...oor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any othe...

Page 4: ...lter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation W LAN optional Orange W LAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to the operating manual of each remote controller The se...

Page 5: ...ion Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the ti...

Page 6: ...y saving that enables power saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped In initial setting this function is activated To deactivate the function consult the installer or authorized service personnel In the Heating mode set the temperature higher than the current room temperature at the beginning of the operation the indoor unit fan rotates at v...

Page 7: ...simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Prog...

Page 8: ... Cooling or Dry mode After the set time has elapsed the air conditioner operation turns off 8 OTHER OPERATIONS 8 1 Powerful operation In the Powerful operation the air conditioner will operate at maximum power and strong airflow to cool down or warm up the room quickly NOTES In multi connection this function cannot be used Press to activate deactivate the Powerful operation When activated the indo...

Page 9: ...s are sold separately When you replace them please contact the store of purchase Cleaning indoor unit body NOTES Do not use water hotter than 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner 1 Wipe the indoor unit body gently with a soft cloth moisten with warm water 2 Wipe the indoor unit body gently with a dry and soft cloth Cleaning air filter 1 Open the intake gri...

Page 10: ...rder to use this function Clean the air filter when the indicator lamp show the following Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and trans...

Page 11: ...lectric shock or damage to the product may occur Do not standing on an unstable platform when installing or removing this product to avoid injury 1 Be sure to turn air conditioner off and to disconnect all the power supply 2 Open the intake grille 3 Open the W LAN adapter cover until it snaps 4 Plug the W LAN adapter into the connection slot of the indoor unit in the direction as shown in the figu...

Page 12: ...emote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case please repeat the remote control...

Page 13: ...may be emitted during the operation 12 4 Multi type air conditioner This indoor unit can be connected to a multi type outdoor unit The multi type air conditioner allows multiple indoor units to be operated in multiple locations The indoor units may be operated simultaneously in accordance with their respective output Simultaneous Use of Multiple Units When using a multi type air conditioner the mu...

Page 14: ...rn Blinking Any state State Causes and solutions See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 9 Filter indicator Clean the air filter and reset the filter sign 9 Demand response operation 7 Error code display Consult authorized service personnel Timer setting error because of Auto restart Reset the clock and timer settings 9 Test run oper...