background image

En-12

Does not operate at all.

 

Has there been a power outage? 
In this case, the unit restarts automatically after the power supply 
is resumed. (Refer to 

page 9

.)

 

Has the circuit breaker been turned off? 

⇒ 

Turn on the circuit breaker.

 

Has a fuse blown out or the circuit breaker been tripped?

⇒ 

Replace the fuse or reset the circuit breaker.

 

Is the timer operating?

 To check or deactivate the timer setting, refer to 

page 5

.

Poor cooling or heating performance.

 

Is the unit operating under the conditions except the permissible 
temperature range? 
In this case, the air conditioner may stop because of the automatic 
protection circuit working.

 

Is the air 

fi

 lter dirty?

 Clean the air 

fi

 lter. (Refer to 

page 8.

 

Is the intake grille or outlet port of indoor unit blocked?

 Remove the obstructions.

 

Is the room temperature adjusted appropriately?

 To change the temperature setting, refer to 

page 5

.

 

Is a window or door left opened?

 Close the window or the door.

 

Is the fan speed set to Quiet? 

 To change the fan speed, refer to 

page 5

.

 

Has the Outdoor Unit Low Noise operation been set? 

 To stop the Outdoor Unit Low Noise operation, refer to

 page 7

.

 

<In the Cooling mode> Is direct or strong sunlight shining into the 
room?

 Close the curtains.

 

<In the Cooling mode> Are there other heating apparatus or com-
puters operating, or too many people in the room?

 Turn the heating apparatus or computers off, or set the tem-

perature lower. (Refer to 

page 5

.)

Air

fl

 ow is weak or stops.

 

Is the fan speed set to Quiet? 

⇒ 

To change the fan speed, refer to 

page 5.

 

Has the Fan Control for Energy Saving set? In this case, the 
indoor unit fan may stop temporarily while the Cooling operation.

⇒ 

To cancel the Fan control for energy saving, refer to 

page 7

.

 

<In the Heating mode> Have you just started the operation? 
In this case, the fan rotates at very low speed temporarily to warm 
up the internal parts of the unit.

 

<In the Heating mode> Is the room temperature higher than the 
set temperature? 
In this case, the outdoor unit stops and the indoor unit fan rotates 
at very low speed. 

 

<In the Heating mode> Is  [  ] indicator blinking? 
In this case, the Automatic defrosting operation is working. The in-
door unit stops for maximum of 15 minutes. (Refer to 

page 9

.)

 

<In the Dry mode> The indoor unit operates at low fan speed to 
adjust the room humidity, and may stop from time to time.

 

<In the Auto mode> While the monitoring operation, the fan 
rotates at very low speed.

Noise is heard.

 

Is the unit operating, or immediate after stopping operation?
In this case, refrigerant 

fl

 owing sound may be heard. It may be 

particularly noticeable for 2-3 minutes after starting operation.

 

Do you hear a slight squeaking sound during the operation? 
This sound is produced by the minute expansion and contraction 
of the front panel caused by temperature change.

 

<In the Heating mode> Do you hear a sizzling sound? 
This sound is produced by the Automatic defrosting operation. 
(Refer to 

page 9

.)

Smell coming from the unit.

 

The air conditioner may absorb various smells generated from 
interior textile, furniture, or cigarette smoke. These smells may be 
emitted during the operation.

 12.4. Multi-type air conditioner

This indoor unit can be connected to a multi-type outdoor unit. 

The multi-type air conditioner allows multiple indoor units to be 

operated in multiple locations. The indoor units may be operated 

simultaneously, in accordance with their respective output.

Simultaneous Use of Multiple Units

 When using a multi-type air conditioner, the multiple indoor units can 

be operated simultaneously, but when 2 or more indoor units of the 
same group are operated simultaneously, the heating and cooling 
ef

fi

 ciency will be less than when a single indoor unit is used alone. 

Accordingly, when you wish to use more than 1 indoor unit for cooling 
at the same time, the use should be concentrated at night and other 
times when less output is required. In the same way, when multiple 
units are used simultaneously for heating, it is recommended that they 
be used in conjunction with other auxiliary space heaters, as required.

 Seasonal and outdoor temperature conditions, the structure of 

the rooms and the number of persons present may also result in 
differences of operating ef

fi

 ciency. We recommend that you try various 

operating patterns in order to con

fi

 rm the level of heating and cooling 

output provided by your units, and use the units in the way that best 
matches your family's lifestyle.

 If you discover that 1 or more units delivers a low level of cooling or 

heating during simultaneous operation, we recommend that you stop 
simultaneous operation of the multiple units.

 Operation cannot be done in the following different operating modes.

  If the indoor unit is instructed to do an operating mode that it cannot 

perform, [  ] indicator on the indoor unit will 

fl

 ash (1 second on, 1 sec-

ond off) and the unit will go into the standby mode. 

 

Heating mode and Cooling mode (or Dry mode)

 

Heating mode and Fan mode 

 Operation can be done in the following different operating modes. 

 

Cooling mode and Dry mode 

 

Cooling mode and Fan mode 

 

Dry mode and Fan mode

 The operating mode (Heating mode or Cooling (Dry) mode) of the out-

door unit will be determined by the operating mode of the indoor unit 
that was operated 

fi

 rst. If the indoor unit was started in the Fan mode, 

the operating mode of the outdoor unit will not be determined. 

  For example, if indoor unit (A) was started in the Fan mode and then 

indoor unit (B) was then operated in the Heating mode, indoor unit (A) 
would temporarily start operation in the Fan mode but when indoor 
unit (B) started operating in the Heating mode, [  ] indicator for indoor 
unit (A) would begin to 

fl

 ash (1 second on, 1 second off) and it would 

go into standby mode.  Indoor unit (B) would continue to operate in 
Heating mode.

13. TROUBLESHOOTING

 WARNING

In the following events, immediately stop operation of 

the air conditioner, and disconnect all the power supply 

by turning off the electrical breaker or disconnecting 

the power plug. Then consult your dealer or authorized 

service personnel.
As long as the unit is connected to the power supply, it 

is not insulated from the power supply even if the unit is 

turned off.
•  Unit smells of something burning or emits smoke
•  Water leaks from the unit

00_9387858037_OM.indb   12

00_9387858037_OM.indb   12

2019/8/26   17:12:04

2019/8/26   17:12:04

Summary of Contents for AOYG12KETA

Page 1: ...er ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di utilizzare l apparecchio leggere...

Page 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Page 3: ...oor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any othe...

Page 4: ...lter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation W LAN optional Orange W LAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to the operating manual of each remote controller The se...

Page 5: ...ion Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the ti...

Page 6: ...y saving that enables power saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped In initial setting this function is activated To deactivate the function consult the installer or authorized service personnel In the Heating mode set the temperature higher than the current room temperature at the beginning of the operation the indoor unit fan rotates at v...

Page 7: ...simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Prog...

Page 8: ... Cooling or Dry mode After the set time has elapsed the air conditioner operation turns off 8 OTHER OPERATIONS 8 1 Powerful operation In the Powerful operation the air conditioner will operate at maximum power and strong airflow to cool down or warm up the room quickly NOTES In multi connection this function cannot be used Press to activate deactivate the Powerful operation When activated the indo...

Page 9: ...s are sold separately When you replace them please contact the store of purchase Cleaning indoor unit body NOTES Do not use water hotter than 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner 1 Wipe the indoor unit body gently with a soft cloth moisten with warm water 2 Wipe the indoor unit body gently with a dry and soft cloth Cleaning air filter 1 Open the intake gri...

Page 10: ...rder to use this function Clean the air filter when the indicator lamp show the following Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and trans...

Page 11: ...lectric shock or damage to the product may occur Do not standing on an unstable platform when installing or removing this product to avoid injury 1 Be sure to turn air conditioner off and to disconnect all the power supply 2 Open the intake grille 3 Open the W LAN adapter cover until it snaps 4 Plug the W LAN adapter into the connection slot of the indoor unit in the direction as shown in the figu...

Page 12: ...emote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case please repeat the remote control...

Page 13: ...may be emitted during the operation 12 4 Multi type air conditioner This indoor unit can be connected to a multi type outdoor unit The multi type air conditioner allows multiple indoor units to be operated in multiple locations The indoor units may be operated simultaneously in accordance with their respective output Simultaneous Use of Multiple Units When using a multi type air conditioner the mu...

Page 14: ...rn Blinking Any state State Causes and solutions See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 9 Filter indicator Clean the air filter and reset the filter sign 9 Demand response operation 7 Error code display Consult authorized service personnel Timer setting error because of Auto restart Reset the clock and timer settings 9 Test run oper...

Reviews: