background image

En-9

8. 

Set the new or washed air cleaning 

fi

 lters into the air 

cleaning 

fi

 lter frames.

NOTES: 

Use the Apple-catechin 

fi

 lter as soon as possible after opening 

the package. The air cleaning effect decreases when the 

fi

 lters 

are left in the opened package.

9. 

Install the air cleaning 

fi

 lter holders to the air 

fi

 lters.

Engage the 4 hooks at the rear of the air cleaning 

fi

 lter frame with 

the latch at both ends of the air 

fi

 lter.

* Take care that the air cleaning 

fi

 lter does not project beyond the 

frame.

Hook (4 places at the rear)

Latch (4 places)

NOTES: 

Take care that the air cleaning 

fi

 lter does not project 

beyond the frame.

10. 

Replace the air 

fi

 lters and close the intake grille. Refer to 

steps 4 ~ 5 of “Cleaning air 

fi

 lter”.

Replacing Ion deodorization 

fi

 lter

1. 

Remove the air 

fi

 lters. Refer to steps 1 ~ 2 of “Cleaning air 

fi

 lter”.

2. 

Remove the Ion deodorization 

fi

 lter (light blue) from the air 

cleaning 

fi

 lter holder.

3. 

Install the new Ion deodorizing 

fi

 lter.

Removing and installing intake grille

 

Removing intake grille

1. 

Open the intake grille until it snaps.

2. 

Pull the mounting shafts while keeping the intake grille in a 

horizontal position.

 

Installing intake grille

1. 

While holding the intake grille horizontal, set the left and 

right mounting shafts into the pillow blocks at the top of the 

front panel.

Insert the shaft until it snaps to latch each shaft properly.

2. 

Close the intake grille.

3. 

Press 6 places on the intake grille to close it completely.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 
Fan mode operation for half a day to dry the internal parts thoroughly 
before the normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the performance even if you have maintained the unit properly.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.

 Filter indicator reset (Special setting)

This function can be used if set correctly during installation. Please 
consult authorized service personnel in order to use this function.

Clean the air 

fi

 lter when the indicator lamp show the 

following:

Indicator lamp

Blinking pattern

 

 

Blinks 3 times, at intervals of 21 seconds

After cleaning, reset the 

fi

 lter indicator by pushing

 

 on the 

indoor unit for 2 seconds or less.

11. GENERAL  INFORMATION

 

Heating performance

This air conditioner operates on the heat-pump principle, absorbing 
heat from air outdoors and transferring that heat to the indoor unit. As a 
result, the operating performance is reduced as outdoor air temperature 
drops.
If you feel that the heating performance is insuf

fi

 cient, we recommend 

you to use this air conditioner in conjunction with other kinds of heating 
appliance.

 

 Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost may 
form on the outdoor unit during the heating operation, and it could 
reduce the operating performance of the product. 
For frost protection, a microcomputer-controlled automatic defrost 
function is equipped in this air conditioner. 
If frost forms, the air conditioner will temporarily stop, and defrost circuit 
will operate brie

fl

 y (maximum of 15 minutes.)

[  ] indicator on the indoor unit blinks during this operation. 
If frost forms on the outdoor unit after the Heating operation, the outdoor 
unit will stop automatically after it operates for a few minutes. Then the 
Automatic defrosting operation starts.

 

 Auto-restart function

In event of power interruption such as a blackout, the air conditioner 
stops once. But it restarts automatically and performs previous operation 
when the power supply is resumed.
If any power interruption occurs after the timer is set, counting down of 
the timer will be reset. 
After the power supply is resumed, [   ] indicator on the indoor unit 
blinks to notify you that there has been a timer fault. In such a case, 
reset the clock and timer settings.

 

Malfunctions caused by other electrical 

devices

Use of other electrical appliances such as an electric shaver or nearby 
use of a wireless radio transmitter may cause the malfunction of the air 
conditioner. 
If you encounter such a malfunction, turn off the circuit breaker once. 
Then turn it on again, and resume operation by using the remote 
controller.

00_9387858037_OM.indb   9

00_9387858037_OM.indb   9

2019/8/26   17:12:04

2019/8/26   17:12:04

Summary of Contents for AOYG12KETA

Page 1: ...er ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di utilizzare l apparecchio leggere...

Page 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Page 3: ...oor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any othe...

Page 4: ...lter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation W LAN optional Orange W LAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to the operating manual of each remote controller The se...

Page 5: ...ion Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the ti...

Page 6: ...y saving that enables power saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped In initial setting this function is activated To deactivate the function consult the installer or authorized service personnel In the Heating mode set the temperature higher than the current room temperature at the beginning of the operation the indoor unit fan rotates at v...

Page 7: ...simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Prog...

Page 8: ... Cooling or Dry mode After the set time has elapsed the air conditioner operation turns off 8 OTHER OPERATIONS 8 1 Powerful operation In the Powerful operation the air conditioner will operate at maximum power and strong airflow to cool down or warm up the room quickly NOTES In multi connection this function cannot be used Press to activate deactivate the Powerful operation When activated the indo...

Page 9: ...s are sold separately When you replace them please contact the store of purchase Cleaning indoor unit body NOTES Do not use water hotter than 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner 1 Wipe the indoor unit body gently with a soft cloth moisten with warm water 2 Wipe the indoor unit body gently with a dry and soft cloth Cleaning air filter 1 Open the intake gri...

Page 10: ...rder to use this function Clean the air filter when the indicator lamp show the following Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and trans...

Page 11: ...lectric shock or damage to the product may occur Do not standing on an unstable platform when installing or removing this product to avoid injury 1 Be sure to turn air conditioner off and to disconnect all the power supply 2 Open the intake grille 3 Open the W LAN adapter cover until it snaps 4 Plug the W LAN adapter into the connection slot of the indoor unit in the direction as shown in the figu...

Page 12: ...emote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case please repeat the remote control...

Page 13: ...may be emitted during the operation 12 4 Multi type air conditioner This indoor unit can be connected to a multi type outdoor unit The multi type air conditioner allows multiple indoor units to be operated in multiple locations The indoor units may be operated simultaneously in accordance with their respective output Simultaneous Use of Multiple Units When using a multi type air conditioner the mu...

Page 14: ...rn Blinking Any state State Causes and solutions See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 9 Filter indicator Clean the air filter and reset the filter sign 9 Demand response operation 7 Error code display Consult authorized service personnel Timer setting error because of Auto restart Reset the clock and timer settings 9 Test run oper...

Reviews: