Fujitsu AOYG12KETA Operating Manual Download Page 7

En-6

5. 

Press 

 to complete the timer setting.

Be close to the indoor unit.

•  To cancel the timer setting during the procedure, press 

 

again.

6.1. Weekly timer

 

Setting details

1. 

Select Weekly timer in step 2 of “Timer setting procedure”.

2. 

Press 

(

)

 to select the program number and the 

day of the week.

Selected program number (1~4) and the day of the week will blink.

Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday

3. 

Press 

.

4. 

Press 

(

)

 to choose the timer operation.

5. 

Press 

.

* When you chose “Without a timer” in step 4, the setting display will 

return to step 1. 

6. 

Press 

(

)

 to set on time or off time.

7. 

Press 

.

* When you chose “Off timer” in step 4, the setting display will return 

to step 1. 

8. 

Press 

(

)

 to set the temperature.

Temperature setting range

Auto, Cooling, or 
Dry mode:

18.0 to 30.0 °C
*Even if you set to 10.0, 16.0-17.5 °C, the air 

conditioner will run at 18.0 °C.

Heating mode: 

10.0 or 16.0 to 30.0 °C

9. 

Press 

.

The setting display will return to step 1.

10. 

Press 

 to complete the setting.

Be close to the indoor unit.

NOTES: 

[   ] indicator on the indoor unit will not turn on even if the 

setting is complete.

•  If you want to return the previous step, press 

 .

•  To check the schedule, use

 

(

)

 

to browse the Weekly 

timer settings in step 1.
To 

fi

 nish checking, press 

 .

•  To deactivate the Weekly timer, press 

 while 

 is 

shown on the remote controller display.
The indicator will disappear.

NOTES:

•  The operation modes will be the same as the mode at the last time 

operation was stopped, so Cooling 

 Heating 

 Cooling 

 Heating 

type of operations cannot be set automatically.

•  If you set the On timer and Off timer on the same time, the On timer 

will work.

•  If two On timers are set on the same time, the air conditioner will run 

in the order of the program number.

Day of the week

Program number

(Without a timer)

(On timer)

(Off timer)

•  You cannot the Weekly timer and the other timers simultaneously.

If you use the On/Off timer, the Program timer, or the Sleep timer 
while the Weekly timer is activated, the Weekly timer will be 
deactivated.
In such a case, activate the Weekly timer after the other timer 

fi

 nishes.

•  If the wired remote controller (optional) is connected, this function is 

restricted.

 

Examples of Weekly timer

Example 1

7:00

9:00

11:00

17:00

23:00

Monday 

to 

Friday

Program 

1

Program 

2

Program 

3

Program 

4

On

Off

On

Off

26 °C

28 °C

Wake up Leave for 

work

Come back 
home

Go to 
sleep

Saturday

(No timer settings)

Sunday

Program 

1

Program 

2

Program 

3

Program 

4

Off

Off

Off

Off

(On)

(On)

(On)

(On)

Example 2: You can specify temperature settings using the On timer in 
the Weekly timer.

7:00

9:00

17:00

23:00

Program 1

Program 2

Program 3

Program 4

On

On

On

On

28 °C

26 °C

27 °C

28 °C

 6.2.  On timer or Off timer

1. 

Select On timer or Off timer in step 2 of “Timer setting 

procedure”.

2. 

Press 

(

)

 to set on time or off time.

Pressing the button: The time will change by +5/-5 minutes.
Pressing down the button: The time will change by +10/-10 minutes.

•  To deactivate the On/Off timer, press 

 while 

 is 

shown on the remote controller display.
The indicator will disappear.

6.3. Program timer

1. 

Set On timer and Off timer. (Refer to “6.2. On timer or Off 

timer”).

2. 

Select Program timer in step 2 of “Timer setting procedure”.

The timer whose setting time is closer to the current time works 

fi

 rst.

The order of the timer operation is displayed as follows:

Timer

Indicator on the remote controller display

On

Off timer

Off

On timer

NOTES:

 You can set the Program timer only within a span of 24 hours.

 6.4. Sleep timer 

1. 

Select Sleep timer in step 2 of “Timer setting procedure”.

2. 

Press 

(

)

 to set the time until the operation 

stops.

Each time you press the button, the time changes as follows:

9H

00M

7H

00M

5H

00M

3H

00M

2H

00M

1H

00M

0H

30M

hours

(30 min.)

•  To deactivate the Sleep timer, press 

 while 

 is shown 

on the remote controller display.
The indicator will disappear.

00_9387858037_OM.indb   6

00_9387858037_OM.indb   6

2019/8/26   17:12:03

2019/8/26   17:12:03

Summary of Contents for AOYG12KETA

Page 1: ...er ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di utilizzare l apparecchio leggere...

Page 2: ...are not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller and...

Page 3: ...oor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product Do not place any othe...

Page 4: ...lter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation Economy Green Economy operation 10 C Heat operation W LAN optional Orange W LAN control is active 3 2 Remote controller When you use the optional remote controller the appearance and the operation procedure may differ For details please refer to the operating manual of each remote controller The se...

Page 5: ...ion Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Activates or deactivates the Weekly timer Activates or deactivates the On timer Off timer or Program timer Activates or deactivates the Sleep timer Starts the timer setting Sends the ti...

Page 6: ...y saving that enables power saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped In initial setting this function is activated To deactivate the function consult the installer or authorized service personnel In the Heating mode set the temperature higher than the current room temperature at the beginning of the operation the indoor unit fan rotates at v...

Page 7: ...simultaneously If you use the On Off timer the Program timer or the Sleep timer while the Weekly timer is activated the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Prog...

Page 8: ... Cooling or Dry mode After the set time has elapsed the air conditioner operation turns off 8 OTHER OPERATIONS 8 1 Powerful operation In the Powerful operation the air conditioner will operate at maximum power and strong airflow to cool down or warm up the room quickly NOTES In multi connection this function cannot be used Press to activate deactivate the Powerful operation When activated the indo...

Page 9: ...s are sold separately When you replace them please contact the store of purchase Cleaning indoor unit body NOTES Do not use water hotter than 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner 1 Wipe the indoor unit body gently with a soft cloth moisten with warm water 2 Wipe the indoor unit body gently with a dry and soft cloth Cleaning air filter 1 Open the intake gri...

Page 10: ...rder to use this function Clean the air filter when the indicator lamp show the following Indicator lamp Blinking pattern Blinks 3 times at intervals of 21 seconds After cleaning reset the filter indicator by pushing on the indoor unit for 2 seconds or less 11 GENERAL INFORMATION Heating performance This air conditioner operates on the heat pump principle absorbing heat from air outdoors and trans...

Page 11: ...lectric shock or damage to the product may occur Do not standing on an unstable platform when installing or removing this product to avoid injury 1 Be sure to turn air conditioner off and to disconnect all the power supply 2 Open the intake grille 3 Open the W LAN adapter cover until it snaps 4 Plug the W LAN adapter into the connection slot of the indoor unit in the direction as shown in the figu...

Page 12: ...emote controller 5 Press The indoor unit enters Button mode and indicator on the indoor unit will blink on off 1sec 1sec When the W LAN adapter find a connectable W LAN access point the blinking will become slowly on off 2sec 0 5sec NOTES If the connection to W LAN access point is not be finished in several minutes Button mode is canceled and turns off In this case please repeat the remote control...

Page 13: ...may be emitted during the operation 12 4 Multi type air conditioner This indoor unit can be connected to a multi type outdoor unit The multi type air conditioner allows multiple indoor units to be operated in multiple locations The indoor units may be operated simultaneously in accordance with their respective output Simultaneous Use of Multiple Units When using a multi type air conditioner the mu...

Page 14: ...rn Blinking Any state State Causes and solutions See page Automatic defrosting operation Please wait until finishing the defrosting maximum of 15 minutes 9 Filter indicator Clean the air filter and reset the filter sign 9 Demand response operation 7 Error code display Consult authorized service personnel Timer setting error because of Auto restart Reset the clock and timer settings 9 Test run oper...