44

Service Supplement

 RX220

Cabling

Appendix

5.2

Cabling

5.2.1

Cable overview

#

Part number/
ASUS No

Description

From

To

1

SNP:A3C40068551/
14G000900700

Operating panel cable

System board 
D2130

Operating 
panel board

2

SNP:A3C40068552/
14G030001900

USB cable 

System board 
D2130

Operating 
panel board

3

SNP:A3C40068547/
14G000900520

IDE cable for 
CD/DVD/CD-RW drive

System board 
D2130

CD/DVD drive

4

SNP:A3C40068548/
14G032804210

I²C bus cable for 
IDTEMP combo

SATA / Fan 
backplane

IDTEMP 
combo

5

SNP:A3C40068550/
14G000900800

Fan control cable

System board 
D2130

Fan 
backplane

6

Mit Lüfter verbunden

Fan control cable

Fan board

Fan 
backplane

7

Mit Lüfter verbunden

Fan control cable

Fan board

Fan 
backplane

8

SNP:A3C40068545/
14G00380170

SATA cable

System board 
D2130

SATA back-
plane resp. 
SATA-HDD

9

SNP:A3C40072583/
14G003801702

SATA cable

System board 
D2130

SATA back-
plane resp. 
SATA-HDD

10

SNP:A3C40068546/
14G030001800

I²C bus cable for SATA 
backplane

System board 
D2130

SATA back-
plane

11

SNP:A3C40068553/
14G000101200

Y power supply cable

PSU plug P4

Non-hot-plug 
SATA-HDD

12

T26139-Y3874-V2

IPMB cable RSB S2 LP

System board 
D2130

RSB S2 LP

13

SNP:A3C40057519

RSB S2 power cable

System board 
D2130

RSB S2 LP

Summary of Contents for Primergy RX220

Page 1: ...20 Server System Service Supplement Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 81730 Munich e mail email manuals fujitsu siemens com Tel 05251 8 14884 Fax 49 700 372 00000 RX220 Sprachen En Edition January 2006 ...

Page 2: ...according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers Gmb...

Page 3: ...l panel board 25 4 4 Replacing the power supply unit 27 4 5 Replacing the internal server power supply cable 31 4 6 Replacing the chassis ID module 33 4 7 Replacing the non hot plug hard disk 34 4 8 Replacing the SATA backplane 36 4 9 Replacing the fan backplane 37 4 10 Replacing the system board 38 5 Appendix 41 5 1 Board layout 41 5 1 1 Control panel board 41 5 1 2 SATA backplane 42 5 1 3 Fan ba...

Page 4: ......

Page 5: ...e performed by service personnel Service DVD A service DVD PRIMERGY is available for Fujitsu Siemens service partners This DVD contains the following manuals as PDF files The Safety manual The Operating Manual for the PRIMERGY RX220 The Technical Manual for the system board D2130 The Options Guide for the PRIMERGY RX220 The D2130 Setup Utility for RX220 manual The Service Supplement for the PRIMER...

Page 6: ... nents Hot plug HDD modules Information about the system board Features of the system board Board layout Jumper settings Replacing the battery Technical Manual Extensions and upgrades I For some components only the instal lation routine is described in the Options Guide Removing this components proceed in reverse order Extending replacing main memory Installing a second processor replacing the pro...

Page 7: ...em board Service Supplement Board layout Cabling BIOS settings D2130 Setup Utility Italics indicate commands menu items or software programs Quotation marks indicate names of chapters and terms that should be emphasized Ê text which follows this symbol describes activities that must be performed in the order shown V CAUTION pay particular attention to text marked with this symbol Failure to observ...

Page 8: ......

Page 9: ...y need the Operating Manual for the server and the Options Guide for the server the Technical Manual for the system board Ê Shut down the server correctly switch it off pull out the power plug and open the server as described in the chapter Replacement routines on page 17 Ê Replace the defective component as described in the relevant chapter Ê Close the server Ê Connect up the server cables 1 Ê Co...

Page 10: ......

Page 11: ...chine Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement is not observed Transport the device only in its original packaging or in packaging which protects it from knocks and jolts Installation and operation V CAUTION If the rack model is integrated in an installation that receives p...

Page 12: ...quirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Route the cables in such a way that they do not form a potential hazard and that they cannot be dama...

Page 13: ... and refresh rates specified in the Technical data section of the monitor description Otherwise you may damage your monitor Batteries V CAUTION Incorrect replacement of batteries may lead to risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer see the Technical Manual for the system board Do not throw batteries into the trash ...

Page 14: ...amaged and imbalanced CDs DVDs can break at high drive speeds data loss Under certain conditions sharp edged pieces of broken CDs DVDs can penetrate the cover of the drive cause damage to the device and be thrown out of the device therefore causing injury to uncovered body parts particularly the face or neck I To protect the CD DVD drive and prevent mechanical damage as well as premature wearing o...

Page 15: ...components that might be damaged by electrostatic discharge ESD are marked with the following label Figure 1 ESD label V CAUTION When you handle components fitted with ESDs you must observe the following points under all circumstances Remove the power plug from the power socket before inserting or removing components containing ESDs You must always discharge static build up e g by touching a groun...

Page 16: ...t the points marked green touch points Do not touch any exposed pins or conductors on a component Place all components on a static free base I You will find a detailed description of handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 ...

Page 17: ... To replace non hot plug components proceed as follows Ê Shut down the operating system Ê Switch the server off Ê Pull the power plug out of the safety socket 4 1 1 Opening closing the server Figure 2 Removing the server Ê Undo the knurled screws 1 and pull the server carefully out of the rack as far as it will go 2 In most cases it makes sense to remove the server from the rack cabinet 1 1 2 ...

Page 18: ...efore you remove it I How to remove the server from the rack cabinet is described in the Operating Manual Figure 3 Taking off the housing cover Ê Undo the knurled screw at the back of the device Ê Push the server cover backward 2 a few centimeters using the recessed grips 3 Ê Lift up the housing cover and remove it To close the cover follow the instructions above in reverse order ...

Page 19: ...e fan modules Figure 4 system fan overview 4 system fan modules consisting of 2 fans each 2 memory fan modules 1 power supply fan module consisting of 2 fans If one fan fails replace this fan to guarantee the required air flow in the system system fans system fans system fans system fans memory fan memory fan power supply fans ...

Page 20: ... 5 System fans V CAUTION A defective fan module must not be replaced during operation Rotating parts involve an increased risk of injury Make sure that the fan blades have stopped turning before removing the fan module Ê Open the server as described in the section Preparation on page 17 ...

Page 21: ...ure 6 Removing a system fan module Ê Pull the plug of the defective system fan module out of the fan board 1 Ê Lift the defective system fan module out of the system Ê Insert the new system fan module Ê Connect the plug of the new system fan module with the fan backplane 1 ...

Page 22: ...of the outward airflow V CAUTION Make sure you install the fan in the correct direction The direction of the outward airflow is indicated on the top of the fan housing and must be the same as that of the other fans Ê Close the server and connect all power plugs for a detailed description see the Options Guide ...

Page 23: ...ement routines Replacing the fans Memory fans Figure 8 Removing installing memory fans Ê Remove the fan module as described on page 21 removing of a system fan Ê Install the fan module as described on page 21 installing of a system fan ...

Page 24: ...e fans Replacement routines Power supply fans Figure 9 Installing removing power supply fans Ê Remove the fan module as described on page 21 removing of a system fan Ê Install the fan module as described on page 21 installing of a system fan ...

Page 25: ...server the ambient temperature is measured on the control panel board If the ambient temperature sensor is defective replace the complete control panel board Ê Open the server as described in the section Preparation on page 17 Figure 10 Opening the maintenance cover of the control panel Ê Undo the screw see figure and lift the maintenance cover carefully to remove the control panel V CAUTION The c...

Page 26: ...panel board Ê Undo both screws see figure Ê Remove the control panel board Ê Insert the new control panel board Ê Fasten the control panel board with the 2 screws Ê Plug the cable on the control panel board Ê Insert the maintenance cover and fasten it with the screw Ê Close the server and connect all power plugs for a detailed description see the Options Guide ...

Page 27: ...ng the power supply unit 4 4 Replacing the power supply unit Ê Open the server as described in the section Preparation on page 17 Figure 12 Removing the power supply unit dummy cover Ê Undo both screws see figure and remove the power supply unit dummy cover ...

Page 28: ...supply cable s connector Ê Pull the internal power supply cable s connector out of the power supply unit and bend it carefully to the side see figure Figure 14 Position of the connectors of the power supply Ê Pull out the connectors of all the cables attached to the power supply unit see 1 6 in the figure above 2 3 1 5 6 4 ...

Page 29: ...upply unit Figure 15 Opening the cable clamp Ê Open the cable clamp Figure 16 Removing the power supply unit from the housing Ê Pull the power supply unit carefully out of the housing I When doing this ensure that the internal power supply cable see circle is not pinched ...

Page 30: ...e the housing V CAUTION Push the cables and connectors carefully through the cable ducts inside the housing see figure to avoid damaging them To install the power supply unit follow the above steps in reverse order Ê Close the server and connect all power plugs for a detailed description see the Options Guide ...

Page 31: ...r power supply cable Ê Open the server as described in the section Preparation on page 17 Ê Remove the power supply unit as described in the section Replacing the power supply unit on page 27 Figure 18 Position of the cable clamps of the internal power supply cable Ê Open the cable clamps and remove the internal power supply cable ...

Page 32: ...p spring on the underside of the line filter access holes are provided both at the side and on the underside of the server housing Ê Now push the line filter out at the rear through the opening in the housing Ê Push the line filter in at the rear through the opening in the housing Ê Insert the internal power cable into the cable clamp and close the cable clamp Ê Close the server and connect all po...

Page 33: ...module and fasten it with the screw Ê Plug the I2 C bus cable Ê Close the server and connect all power plugs for a detailed description see the Options Guide I To enable ServerView and ServerStart to identify the system the Chassis ID Prom must be reprogrammed using the Chassis ID Prom tool after the new chassis ID module has been installed You will find this tool on the ServerSupport CD or you ca...

Page 34: ... 4 7 Replacing the non hot plug hard disk The non hot plug hard disk is accommodated in a sturdy mounting assembly and must be dismounted in order to replace it Figure 21 Mounting assembly with a non hot plug hard disk Ê Open the server as described in the section Preparation on page 17 ...

Page 35: ...essed to pull it out This is on the underside here and therefore cannot be seen Ê Loosen the hard disk housing s knurled screw 2 Ê Pull the hard disk mounting assembly out Ê Remove the hard disk from the mounting assembly by undoing the four screws see figure 21 on page 34 Ê Install the non hot plug hard disk following the above steps in reverse order Ê Close the server and connect all power plugs...

Page 36: ...ly Figure 23 Removing the SATA backplane Ê Loosen the knurled screw see figure from the SATA backplane then move the backplane to the direction of the arrow until its holes disengage from the housing stand offs Lift the SATA backplane then set it aside Ê Install the new SATA backplane match its holes with the housing stand offs then move it to the opposite direction to lock I Be careful of the har...

Page 37: ...s from the fan backplane Figure 24 Removing the fan backplane Ê Loosen the knurled screw see figure from the fan backplane then move the backplane to the direction of the arrow until its holes disengage from the housing stand offs Lift the fan backplane then set it aside Ê Install the new fan backplane match its holes with the housing stand offs then move it to the opposite direction to lock Ê Con...

Page 38: ...ules the relevant procedure is described in the Options Guide Ê Remove the air duct the heat sink s and processor s the relevant procedure is described in the Options Guide Ê Remove the riser card holders the relevant procedure is described in the Options Guide Ê Remove all cables connected to the system board Figure 25 Positions of the screws on the system board Ê Remove 11 system board screws se...

Page 39: ...th 11 screws Ê Reconnect all cables I For cabling information see section Cabling on page 44 Ê Reinstall the riser card holders the relevant procedure is described in the Options Guide Ê Reinstall the air duct the heat sink s and processor s the relevant procedure is described in the Options Guide Ê Reinstall the memory modules the relevant procedure is described in the Options Guide Ê Close the s...

Page 40: ......

Page 41: ...board layout of the system board is described in the Technical Manual of the system board D2130 5 1 1 Control panel board Part number SNP A3C40066829 Figure 26 Control panel board Connection 1 USB34 connector on system board 2 PANEL1 connector on system board 1 2 ...

Page 42: ...ector assignment on the SATA backplane Connection 1 Power supply 2 SATA LED controller connector I2C_SATA1 on system board 3 SATA1 connector on system board 4 SATA2 connector on system board 5 SATA HDD1 data and power connector 6 SATA HDD2 data and power connector 7 IDTEMP Combo board SNP A3C40038146 1 2 3 4 5 6 7 ...

Page 43: ...ngle system fan module for memory modules 3 Double system fan module for CPU2 4 Double system fan module for CPU2 5 Double system fan module for CPU1 6 Double system fan module for CPU1 7 Single system fan module for memory modules 8 PANEL2 connector on system board 9 PSU signal connector from power supply unit 10 Power plug from power supply 11 IDTemp Combo board SNP A3C40038146 1 2 3 4 5 6 7 8 9...

Page 44: ...50 14G000900800 Fan control cable System board D2130 Fan backplane 6 Mit Lüfter verbunden Fan control cable Fan board Fan backplane 7 Mit Lüfter verbunden Fan control cable Fan board Fan backplane 8 SNP A3C40068545 14G00380170 SATA cable System board D2130 SATA back plane resp SATA HDD 9 SNP A3C40072583 14G003801702 SATA cable System board D2130 SATA back plane resp SATA HDD 10 SNP A3C40068546 14G...

Page 45: ...able connections of the RX220 hot plug B M C H a r d d i s k 2 H a r d d i s k 1 C D R O M D V D C D R W O p e r a t i n g p a n e l P o w e r s u p p l y u n i t S A T A b a c k p l a n e F a n b a c k p l a n e I D T E M P C o m b o P 5 P 4 P 3 P 1 P 2 S A T A 1 S A T A 2 S A T A 1 S A T A 2 R S B S 2 L P ...

Page 46: ...e 30 Cable connections of the RX220 non hot plug H a r d d i s k 2 H a r d d i s k 1 C D R O M D V D C D R W O p e r a t i n g p a n e l P o w e r s u p p l y u n i t F a n b a c k p l a n e I D T E M P C o m b o P 5 P 4 P 3 P 1 P 2 S A T A 1 S A T A 2 R S B S 2 L P B M C ...

Page 47: ...tery exchange 13 M meaning of the symbols 7 N non hot plug hard disk replace 34 notational conventions 7 note about the laser 15 notes on handling CDs 14 P power supply unit dummy cover 27 internal server power supply cable 31 Position of connectors 28 replace 27 R remove housing cover 18 replace chassis ID module 33 fan backplane 37 line filter 32 non hot plug hard disk 34 SATA backplane 36 syste...

Page 48: ...48 Service Supplement RX220 Index system fans replace 19 T target group 5 ...

Page 49: ...0 Server System RX220 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Page 50: ......

Page 51: ...0 Server System RX220 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Page 52: ......

Page 53: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Reviews: