Replacement routines
Replacing the fan backplane
Ê
Connect the cables of the accessible drives.
Ê
Close the server and connect all power plugs (for a detailed description see
the Options Guide).
4.9
Replacing the fan backplane
Ê
Open the server as described in the
section “Preparation” on page 17
Ê
Remove all the cables from the fan backplane.
Figure 24: Removing the fan backplane
Ê
Loosen the knurled screw (see figure) from the fan backplane, then move the
backplane to the direction of the arrow until its holes disengage from the
housing stand-offs.
Lift the fan backplane, then set it aside.
Ê
Install the new fan backplane, match its holes with the housing stand-offs
then move it to the opposite direction to lock.
Ê
Connect all cables to the fan backplane (see
Ê
Close the server and connect all power plugs (for a detailed description see
the Options Guide).