1 - 18
Mounting Procedure
6
MJ2
MJ1
DC 24
V
(+)
(-)
TB1
Fixture
Mounting hole
Mounting hole
Mounting panel
UGx20
Mounting Procedure
1
Cut out the mounting panel (Max. thick: 3.2 mm) to match the dimensions shown below.
2
Insert the fixtures attached to UGx20 into the mounting holes on UGx20. Tighten them with the locking
screws. (Number of the fixtures: all series 4 pcs,)
3
The waterproof packing mounted on the UG221 main unit shall come in close contact with the mounting
panel so that it is surely caught between the mounting panel and UG221.
Mounting panel
Cut-out
1
6
5
.5
+0.5
- 0
220.5
+0.5
- 0
Dimensions of Fixtures
for UG220/320
for UG221/420/520
17.8
10.5
30.0
(Unit : mm)
17.8
10.5
20.0
165.5
220.5
Unit : mm
+0.5
- 0
- 0
+0.5
246.2
313
UG520
UG320
216.2
289
+0.5
- 0
- 0
+0.5
UG420
131
174
+0.5
- 0
- 0
+0.5
+0.5
- 0
- 0
+0.5
UG220
UG221
6 Mounting Procedure
torque:
UG320/UG221/UG220
0.3 to 0.5 N • m
UG520/UG420
0.5 to 0.7 N • m