12 - 8
INP-TN4PHAV-E
Content
To change the recording and print color of each channel.
Max. 1-day lots (lots of max. 24 data items) of the instantaneous values at
each full hour for each channel each day are stored and printed out. At the
same time, maximum values, minimum values and average values are
printed out too. The operation is turned on/off for individual channels and
the operation start time is specified from the keyboard.
Max. 1-day lots (lots of max. 24 data items) of the integration values for 1-
hour periods in each channel each day are stored and printed out. At the
same time, maximum values, minimum values and average values are
printed out too. The operation is turned on/off for individual channels and
the operation start time is specified from the keyboard.
Set data and clock functions are protected by a lithium battery incorporated
in the recorder. (Battery life is about 10 years at normal temperature.)
Filter function for delaying the response of each channel to counter sharp
changes in input. (Primary delay filters)
Time constant setting range: 0 to 900 seconds (set from the keyboard)
If thermocouple or resistance bulb wire breakage occurs, there is a swing to
the maximum value of recording range and at the same time a display is
given and a printed record is made.
Used to hold alarm display and alarm output even after alarm is recovered.
ON/OFF operation is made form the keyboard. Alarm in hold mode is
released by external control (DI)
Used to copy the value, which has been set in any channel, to another
channel.
Function
Recording color change
function
Daily report function
Data sum function
Memory backup
function
Input filter
Burn-out function
Alarm latch function
Set value copying
function