Chapter 1  BEFORE USING THE REMOTE KEYPAD "TP-E1" 

1.1 Check 

Points 

Unpack the package and check the following: 

(1)  The package contains the Remote Keypad and its instruction 

manual (this book). 

(2)  There have been no problems during transportation. In 

particular, no parts are damaged or have fallen out of place 
nor are there any dents on the body. 

(3)  The model name "TP-E1" is inscribed on the back of the 

Remote Keypad as shown in Figure 1.1. 

If you find any anomalies, contact your dealer or nearest Fuji 
Electric sales office. 

Model name 

Figure 1.1  Back of Remote 

Keypad TP-E1 

1.2  Inverters with which the Remote Keypad Interfaces 

The Remote Keypad TP-E1 interfaces with the following Fuji inverters:  

Series 

Type of inverter

*

Remarks

FRENIC-Mini FRN

†††

C1S-

††††

FRN

†††

C1E-

††††

(

Each 

†

 has its meaning 

as shown below, 
represented by an 
alphanumeric character.

)

 

The Remote Keypad is fully supported by inverters with 
a ROM version of C1S10500 or above. (You can check 
the inverter’s ROM version by entering 

5_14

 in 

"Maintenance Information" (Menu #5) in Program 
Mode.) 

There are restrictions on the support for the Remote 
Keypad TP-E1 by inverters with a ROM version of 
C1S10499 or below. For details, contact your Fuji 
Electric sales office. 

* Type of inverter 

 

  For the details of the Inverter type ID, refer to the FRENIC-Mini Instruction Manual 

(INR-SI47-0791-E), Chapter 1, Section 1.1 "Acceptance Inspection." 

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for Frenic Mini TP-E1

Page 1: ...ling blocks correct operation or causes a short life or failure Deliver this manual to the end user of the product Keep this manual in a safe place until the Remote Keypad is discarded For the usage o...

Page 2: ...ten permission from Fuji Electric FA Components Systems Co Ltd All products and company names mentioned in this manual are trademarks or registered trademarks of their respective holders The informati...

Page 3: ...unction with this manual as necessary FRENIC Mini User s Manual MEH446 RS485 Communications User s Manual MEH448 Catalog MEH441 MEH451 Application Guide MEH449 FRENIC Mini Instruction Manual INR SI47...

Page 4: ...le the key Prepare an emergency stop switch separately If you disable the STOP key priority function and enable command FWD or REV you cannot stop the inverter output by the key on the built in keypad...

Page 5: ...rol circuit wires come into direct contact with the live main circuit terminal therefore the sheath may break Accordingly there is a possibility that high voltage on the main circuit may be applied to...

Page 6: ...G THE REMOTE KEYPAD TP E1 This chapter describes the functions of the Remote Keypad including data copying as well as how to operate the Remote Keypad Chapter 4 SPECIFICATIONS This chapter lists the g...

Page 7: ...essories and Parts Required for Connection 2 1 2 2 Installing the Remote Keypad 2 2 Chapter 3 OPERATION USING THE REMOTE KEYPAD TP E1 3 1 3 1 Familiarizing Yourself with the Remote Keypad 3 1 3 2 Oper...

Page 8: ...aces The Remote Keypad TP E1 interfaces with the following Fuji inverters Series Type of inverter Remarks FRENIC Mini FRN C1S FRN C1E Each has its meaning as shown below represented by an alphanumeric...

Page 9: ...Remarks Remote Operation Extension Cable Note 1 CB 5S CB 3S or CB 1S You have a choice of three lengths 5 m 3 m and 1 m RS485 Communications Card OPC C1 RS Install this into the inverter Screws for mo...

Page 10: ...closure e Install the RS485 Communications Card on the inverter f Insert the connector on one end of the Remote Operation Extension Cable or LAN cable into the RJ 45 modular jack on the Remote Keypad...

Page 11: ...nsions of Square Hole and Screw Holes d Mount the Remote Keypad TP E1 onto the enclosure with 2 screws as shown in Figures 2 3 and 2 4 Recommended tightening torque 0 7 N m Figure 2 4 Mounting Remote...

Page 12: ...ect contact with the live main circuit terminal therefore the sheath may break Accordingly there is a possibility that high voltage on the main circuit may be applied to the control circuit wires It i...

Page 13: ...close the TB cover Take care not to pinch control signal wires cables between the TB cover and the body of the FRENIC Mini f Insert the connector on one end of the Remote Operation Extension Cable or...

Page 14: ...or EMC compliance using clamps provided Figure 2 9 Shielded Wire Connection to Comply with EMC Directives Figure 2 10 Grounding Shields to Comply with EMC Directives For EMC directives refer to the FR...

Page 15: ...sed to selects the setting items displayed on the LED monitor and change the function code data key Starts the motor Keys key Stops the motor RUN LED Lights when a Run command is given to the Inverter...

Page 16: ...peed output current A output voltage V timer s input power kW PID process command and PID feedback amount In speed monitoring one of the following can be selected output frequency before slip compensa...

Page 17: ...copied is summarized in the FRENIC Mini Instruction Manual INR SI47 0791 E Chapter 5 the Data copy column of Section 5 1 Function Code Tables using the following designations Y Can be copied unconditi...

Page 18: ...ng data copying operation while Table 3 4 shows details of the data copying functions The memory of the Remote Keypad can save function code data for one inverter Figure 3 2 Status Transition during D...

Page 19: ...in the memory of the Remote Keypad into the inverter Pressing the key during the write operation while CoPy is blinking aborts the write copy operation causing E to blink on the LED monitor see Note...

Page 20: ...ter during data copying the appears on the monitor and the following problems will arise with the Remote Keypad and or inverter depending upon the actual operation being in progress Take the necessary...

Page 21: ...low Note Atmospheric pressure 86 to 106 kPa Vibration 3 mm max 2 9 Hz 9 8 m s 2 9 20 Hz 2 m s 2 20 55 Hz 1 m s 2 55 200 Hz Ambient temperature during storage 25 to 70 C Ambient humidity during storage...

Page 22: ...ce for Remote Keypad 5 V 2 7 GND Signal ground GND 3 6 NC Unassigned reserved 4 DX RS485 communication data 5 DX RS485 communication data Note SW1 for the terminating resistor on the RS485 Communicati...

Page 23: ...e FRENIC Mini series of inverters Please feel free to send your comments regarding any errors or omissions you may have found or any suggestions you may have for generally improving the manual In no e...

Page 24: ...Fuji Electric FA Components Systems Co Ltd 2003 6 c03 c03 1CM Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Reviews: