5.3 Manual operation
The section explains the control input signals to run or control the motor speed at the ON level.
Control input signal :
・
Forward command [FWD] (2)
Control output signal :
・
Deviation zero (23)
・
Reverse command [REV] (3)
・
Deviation excessive [OF]
・
Pulse train ratio 1 (27)
(alarm detection is issued)
・
Pulse train ratio 2 (28)
・
Speed zero [NZERO] (24)
・
Deviation clear (50)
・
Speed arrive [NARV] (25)
・
Multistep speed selection X 1 [X1] (51)
・
Multistep speed selection X 2 [X2] (52)
・
Multistep speed selection X 3 [X3] (53)
・
Acceleration/deceleration
time selection [ACC0] (14)
・
Speed command [NREF] (fixed)
5.3.1 Forward command [FWD] / Reverse command [REV]
These signals rotate the motor.
Forward command [FWD] / Reverse command [REV] (Control input signal)
■
Function
While the [FWD] ([REV]) signal is on, the motor rotates forward (in reverse). Acceleration starts at the ON edge, deceleration starts at the
OFF edge.
Simultaneous turning on both [FWD] and [REV], does not stop the motor.
The motor rotates at a speed selected by multistep speed selection [X1], [X2] or [X3].
Multistep speed selection [X1], [X2], [X3]
[X3] [X2] [X1]
Speed
OFF OFF OFF
OFF OFF ON
OFF ON OFF
OFF ON ON
ON OFF OFF
ON OFF ON
ON ON OFF
ON ON ON
(See below.)
Speed set by basic para. 01
Speed set by basic para. 02
Speed set by basic para. 03
Speed set by basic para. 04
Speed set by basic para. 05
Speed set by basic para. 06
Speed set by basic para. 07
Basic type (DI/DO) : [NREF] terminal
SX bus type (SX bus direct connection) : IQ area (+10, +11)
T-link type (T-link direct connection) : WB area (+7, +8)
■
Parameter setting
To allocate the [FWD] signal to the control input terminal, set (2) to the system para. (set (3) for the [REV]).
If these signals are not allocated to the control input terminal, these signals are deemed "always off".
■
Related items
(1) Changeover of acceleration/deceleration time
The accel. and decel.(*) time of motor can be set by basic para. 21 to 24. The accel. time and decel. time can be set separetely.
The accel. time is set by the basic para. 21 or 23, regardless of rotational direction.
Note: (*) Accel. : Acceleration, Decel. : Deceleration
Min. value in IQ area and WB area is
equivalent to 0.01 [r/min].
Summary of Contents for Faldic-a RYS-R Series
Page 1: ...RYS R Type User s Manual MHT260a Engl...
Page 2: ...0...
Page 78: ...0...
Page 79: ...0 1 1 1 23 1 4 5 6 1 7 8 1 2 8 1 1 1 1 1 1 1 1 9 9 9 9 9 0 1 9 1 9 1 9 1 9 1 9 1...
Page 81: ...0 1 20 3 4 2 20 5 20 5 4 2 3 4 4 6 4 72 4 7 4...
Page 83: ...0 0 0 0 0 0 1 1 2 3 4 0 1 0 5 6 1 0 6 7 0 0 8 0 9 5 5 2 9 0 6 4 5 5 2 3 9 7 9 7 9 5 5 4 6 6...
Page 84: ...6 7 A 6 B C D5 7 4 4 6 4 5 1 BE8 F70 CPU...
Page 85: ...0 1 2 3 4 3 3 3 5 1 678...
Page 86: ...0 1 1 0 1 2 2 3 4 5 4 5 2 1 678 4 9 95 9 9 1 9 1 3 3 1 4 5 06 2 3 0 06 4 4 0 0 0 0 0 3 4 0...
Page 87: ...0 0 0 A A 0 0 0 0 0 0...