INSTALLATION AND ASSEMBLY
18
HEATING UNIT CONNECTION
1. Attach heat cables or heat switch cord amphenols into the heating device (typically a HB-01
or HB-02W unit).
2. Make sure the temperatures on the read out reach the set points.
TIMING UNIT CONNECTION
1. Connect gun switch cord to 3-prong amphenol.
2. Connect air solenoid switch cord to 2-prong amphenol.
3. Plug timer into 110-volt outlet.
NOTE: Timers are precision instruments and extreme care should be taken to prevent abuse.
TIMER TEST PROCEDURE
This is the point to test the operation of the timer without dispensing chemical.
1. Turn Timer Power Switch to the ON position.
2. Set timer to AUTO position.
3. Set timer for 10 seconds.
4. Make sure that the Slide Safety Valve is in the OFF (or back) position and that all SLUG PRO gun ball
valves are in the closed position.
5. For DT Timer, press trigger button once. At this point the timer should start and stop counting after
10 seconds. If not, the timer and/or connections are not functioning properly.
For MT Timer, press trigger button once. Pre-set shot time will be displayed. Press trigger button
a second time to begin shot sequence.
6. Press trigger again, but before the timer counts down 10 seconds, press the trigger again to stop the
count. If the count does not stop, the timer and/or connections are not functioning properly.
THE FSI FOAM UNIT IS NOW READY FOR TEST AND OPERATION!
www.foamsupplies.com
|
www.ecomatetechnology.com
|
1.800.325.4875
Summary of Contents for PROFESSIONAL Series
Page 2: ...www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 7: ...PROCESS DESCRIPTION ...
Page 10: ...5 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 11: ...EQUIPMENT DESCRIPTION ...
Page 16: ...11 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 17: ...CHEMICAL PREPARATION STORAGE HANDLING ...
Page 21: ...INSTALLATION ASSEMBLY ...
Page 24: ...19 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 25: ...PRODUCTION AND QUALITY CONTROL ...
Page 32: ...27 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 34: ...29 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 35: ...CHANGING CHEMICAL CYLINDERS ...
Page 40: ...35 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 41: ...MAINTENANCE ...
Page 49: ...TROUBLESHOOTING ...
Page 57: ...SAFETY HANDLING ...
Page 62: ...57 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...
Page 63: ...EQUIPMENT DRAWINGS PARTS ...
Page 64: ...59 www foamsupplies com www ecomatetechnology com 1 800 325 4875 ...