PrimAer 28GHz
Operating Manual
⑥
AOM
This item is configured with the 'LD' alarm and 'PD' alarm which can monitor the SU's internal analog
optic module RF & optic's SISO path / MIMO path DL/UL real-time RF output, and converted analog
optic signal transmission/reception strength, along with Array Ant. atten control, ATT control, ALC limit
level setting, and ALC on/off.
- DL Output : AOM SISO/MIMO IF DL output real-time monitoring
- DL ATT : AOM SISO/MIMO IF DL Atten control
- DL ISO ATT : AOM SISO/MIMO IF DL Isolation Atten monitoring
- UL Output : AOM SISO/MIMO IF UL output real-time monitoring
- UL ATT : AOM SISO/MIMO IF UL Atten control
- UL Cas ATT : AOM SISO/MIMO IF UL Cascade Atten control
- ALC Limit Level : AOM SISO/MIMO IF ALC limit level setting
- ALC On/Off : AOM SISO/MIMO IF ALC function On/Off control
- Front End ATT : Array Ant. DL/UL SISO/MIMO Atten control
- LD : AOM SISO/MIMO DL LD Power real-time monitoring
- LD Lower : AOM SISO/MIMO DL LD Power lower value setting and alarm display
- PD : AOM SISO/MIMO UL PD Power real-time monitoring
- PD Lower : AOM SISO/MIMO UL PD Power lower value setting and alarm display
- Next LD : Cascaded SU AOM SISO/MIMO DL LD Power real-time monitoring
- Next LD Lower : Cascaded SU AOM SISO/MIMO DL LD Power lower value setting and alarm display
- Next PD : Cascaded SU AOM SISO/MIMO UL PD Power real-time monitoring
- Next PD Lower : Cascaded SU AOM SISO/MIMO UL PD Power lower value setting and alarm display