with cable shielded with aluminum or copper material sheath.
•
The metal used for each unit of the PrimAer 28Ghz are designed to withstand not only commonly
known corrosion, but also localized corrosion including stress corrosion and cracking.
•
The plastic used should not melt by solvent, and is created so that crack, melt or color change do
not occur when exposed to ammonia.
•
The plastic is created so that it does not crack when exposed to materials(eg. insulation, filing
compound, etc).
•
The enclosure, components, PCB, solders, cables, etc applied for each unit of the PrimAer 28GHz
comply with RoHS (Restriction of hazard materials).
4.3 Electrical Specification
•
The power from the Rectifier operates normally on commercial power(AC100 ~240V/60Hz).
•
It has over-power, over-voltage protection function on the user power.
•
In case of black out, the equipment RF setting value automatically returns to the previous status
right before the black out.
•
The equipment ground is located on both sides of the enclosure.
•
The components used in the PrimAer 28 satisfy the EMI terms of FCC regulation Title 47, Part 15,
Subject J, Class A.
•
A grounding rod capable of grounding the grounding wire conforming to #6AWG must be attached
to the enclosure.
Unit
Operating Voltage
Range
Output
Voltage/Current
Range
Remark
Rectifier
AC 100Vac~240Vac
60Hz ( 57 ~ 63Hz )
Port 1: -53.5V/2.44A
Port 2: -53.5V/2.44A
Port 3: -53.5V/2.44A
Port 4: -53.5V/2.44A
Battery: -53.5V/3A