PrimAer 28GHz
Operating Manual
- RSRP Req : Item to recheck RSRP of the input signal from the DU
- PLL Relock : Item to reset PLL from the DU
- Beam Scan : Item to reoperate DU beamforming function
⑦
AOM
This item is configured with the 'LD' alarm and 'PD' alarm which can monitor the DU's internal analog
optic module RF & optic's SISO path / MIMO path DL/UL real-time RF output, and converted analog
optic signal transmission/reception strength, along with Array Ant. atten control, ATT control, ALC limit
level setting, and ALC on/off.
- DL Output : AOM SISO RF, AOM MIMO RF DL output real-time monitoring
- DL ATT : AOM SISO RF, AOM MIMO RF DL Atten control
- ALC Limit Level : AOM SISO RF DL/UL, AOM MIMO RF DL/UL Auto Limit Control limit level setting
- ALC On/Off : AOM SISO RF DL/UL, AOM MIMO RF DL/UL Auto Limit Control function On/Off control
- UL Output : AOM SISO RF, AOM MIMO RF UL output real-time monitoring
- UL ATT : AOM SISO RF, AOM MIMO RF UL Atten control
- UL ISO ATT : AOM SISO/MIMO IF UL Isolation Atten monitoring
- Front End ATT : Array Ant. DL/UL SISO/MIMO Atten control
- LD : AOM SISO OPTIC DL, AOM MIMO DL LD Power real-time monitoring
- LD Lower : AOM SISO OPTIC DL, AOM MIMO DL LD Power lower value setting & alarm showing
- PD : AOM SISO OPTIC UL, AOM MIMO UL LD Power real-time monitoring
- PD Lower : AOM SISO OPTIC UL, AOM MIMO UL PD Power lower value setting & alarm showing